Aleta.hr
Main Product Image

MSC-DM-10-M7(24VDC)/MSFA

Code: 1746806

ManufacturerEaton (Moeller)
Catalog number191110
EAN code4015081916085
Order only
Zagreb0 pcs
Zadar0 pcs

Sign in or create an account for lower prices and other benefits


WSP*
147,03 €
Neto147,03
RP183,79
pcs

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Yes

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated control supply voltage Us at AC 50HZ

0 - 0V

Rated operation current Ie

6.6A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated conditional short-circuit current, type 2, 230 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

7A

Overload release current setting

6.3 - 10A

Rated conditional short-circuit current, type 2, 400 V

100A

Rated operation power at AC-3, 400 V

3kW

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally open contact

1

Power consumption

2.6W

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Yes

Release class

CLASS 10 A

Number of command positions

0

With fuse

No

Type of electrical connection of main circuit

Screw connection

Degree of protection (NEMA)

Other

With transformer

No

Coordination class according to IEC 60947-4-3

Class 1

Number of indicator lights

0

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 - 24V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Voltage type for actuating

DC

External reset possible

No

Suitable for emergency stop

No

Supporting protocol for AS-Interface Safety at Work

No

Rail mounting possible

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Height

180mm

Depth

115mm

Width

45mm

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for LON

No

Supporting protocol for TCP/IP

No

Supporting protocol for DeviceNet

No

Supporting protocol for CAN

No

Supporting protocol for PROFIBUS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for ASI

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for Modbus

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Data-Highway

No

Supporting protocol for INTERBUS

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DM-10-M7(24VDC)/MSFA

Main Product Image

Code

1746806

Catalog number

191110

Type

Motor starter/Motor starter combination

Manufacturer

Eaton (Moeller)

Serie

-

Neto WSP:

147,03

RP:183,79
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated operation current Ie

6.6A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated conditional short-circuit current, type 2, 230 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

7A

Overload release current setting

6.3 .. 10A

Rated conditional short-circuit current, type 2, 400 V

100A

Rated operation power at AC-3, 400 V

3kW

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally open contact

1

Power consumption

2.6W

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Release class

CLASS 10 A

Number of command positions

0

With fuse

Type of electrical connection of main circuit

Screw connection

Degree of protection (NEMA)

Other

With transformer

Coordination class according to IEC 60947-4-3

Class 1

Number of indicator lights

0

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 .. 24V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Voltage type for actuating

DC

External reset possible

Suitable for emergency stop

Supporting protocol for AS-Interface Safety at Work

Rail mounting possible

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Height

180mm

Depth

115mm

Width

45mm

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for LON

Supporting protocol for TCP/IP

Supporting protocol for DeviceNet

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for Foundation Fieldbus

Supporting protocol for ASI

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for Modbus

Supporting protocol for EtherNet/IP

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.