Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 50HZ
230 - 230V
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 - 0V
Rated operation power at AC-3, 400 V
3kW
Overload release current setting
6.3 - 10A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
7A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
6.6A
Number of auxiliary contacts as normally open contact
1
Type of motor starter
Direct online starter (DOL)
Rated conditional short-circuit current, type 2, 230 V
0A
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Yes
Suitable for emergency stop
No
Power consumption
1.4W
With transformer
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Release class
CLASS 10 A
Ambient temperature, upper operating limit
55°C
Number of command positions
0
With fuse
No
With short-circuit release
Yes
Number of indicator lights
0
External reset possible
No
Type of electrical connection of main circuit
Screw connection
Supporting protocol for PROFIBUS
No
Supporting protocol for TCP/IP
No
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Supporting protocol for Modbus
No
Coordination class according to IEC 60947-4-3
Class 1
Degree of protection (NEMA)
Other
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Rail mounting possible
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for ASI
No
Degree of protection (IP)
IP20
Rated conditional short-circuit current, type 2, 400 V
100A
Supporting protocol for LON
No
Rated control supply voltage Us at AC 60HZ
0 - 0V
Supporting protocol for CAN
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
45mm
Height
180mm
Depth
115mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-DM-10-M7(230V50HZ)/MSFA

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 .. 0V
Rated operation power at AC-3, 400 V
3kW
Overload release current setting
6.3 .. 10A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
7A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
6.6A
Number of auxiliary contacts as normally open contact
1
Type of motor starter
Direct online starter (DOL)
Rated conditional short-circuit current, type 2, 230 V
0A
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Suitable for emergency stop
Power consumption
1.4W
With transformer
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Release class
CLASS 10 A
Ambient temperature, upper operating limit
55°C
Number of command positions
0
With fuse
With short-circuit release
Number of indicator lights
0
External reset possible
Type of electrical connection of main circuit
Screw connection
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Supporting protocol for Modbus
Coordination class according to IEC 60947-4-3
Class 1
Degree of protection (NEMA)
Other
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Rail mounting possible
Supporting protocol for EtherNet/IP
Supporting protocol for ASI
Degree of protection (IP)
IP20
Rated conditional short-circuit current, type 2, 400 V
100A
Supporting protocol for LON
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for CAN
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
180mm
Depth
115mm
From same serie
We use cookies to enhance your experience.