Aleta.hr
Main Product Image

MSC-DM-0,63-M7(230V50HZ)/MSFA

Code: 1746801

ManufacturerRAZNO
Catalog number191116
Type
EAN code4015081916146

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

With short-circuit release

Yes

Rated control supply voltage Us at DC

0 - 0V

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated operation power at AC-3, 400 V

0.18kW

Rated operation current at AC-3, 400 V

0.63A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated operation power at AC-3, 230 V, 3-phase

0.09kW

Rated operation current Ie

0.6A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Number of auxiliary contacts as normally open contact

1

Overload release current setting

0.4 - 0.63A

Number of auxiliary contacts as normally closed contact

0

Rated power, 575 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Yes

Release class

CLASS 10 A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

Yes

Type of electrical connection of main circuit

Screw connection

Suitable for emergency stop

No

With transformer

No

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 2

External reset possible

No

Number of indicator lights

0

With fuse

No

Supporting protocol for PROFIBUS

No

Supporting protocol for TCP/IP

No

Supporting protocol for INTERBUS

No

Degree of protection (IP)

IP20

Supporting protocol for CAN

No

Supporting protocol for ASI

No

Supporting protocol for LON

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Modbus

No

Supporting protocol for Data-Highway

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for DeviceNet

No

Degree of protection (NEMA)

Other

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Supporting protocol for PROFIsafe

No

Width

45mm

Height

180mm

Depth

115mm

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for AS-Interface Safety at Work

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DM-0,63-M7(230V50HZ)/MSFA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

With short-circuit release

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 400 V

0.18kW

Rated operation current at AC-3, 400 V

0.63A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

0.09kW

Rated operation current Ie

0.6A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Number of auxiliary contacts as normally open contact

1

Overload release current setting

0.4 .. 0.63A

Number of auxiliary contacts as normally closed contact

0

Rated power, 575 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Release class

CLASS 10 A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

Type of electrical connection of main circuit

Screw connection

Suitable for emergency stop

With transformer

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 2

External reset possible

Number of indicator lights

0

With fuse

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Degree of protection (IP)

IP20

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet

Degree of protection (NEMA)

Other

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Supporting protocol for PROFIsafe

Width

45mm

Height

180mm

Depth

115mm

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.