Aleta.hr
Main Product Image

MSC-DM-0,25-M7(230V50HZ)/MSFA

Code: 1746797

ManufacturerRAZNO
Catalog number191114
Type
EAN code4015081916122

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated operation power at AC-3, 400 V

0.06kW

Rated control supply voltage Us at DC

0 - 0V

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.04kW

Rated operation current at AC-3, 400 V

0.25A

Overload release current setting

0.16 - 0.25A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

With short-circuit release

Yes

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

0.21A

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Voltage type for actuating

AC

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 2

Number of indicator lights

0

Number of command positions

0

Temperature compensated overload protection

Yes

Supporting protocol for TCP/IP

No

With transformer

No

Degree of protection (IP)

IP20

Release class

CLASS 10 A

Rail mounting possible

Yes

Suitable for emergency stop

No

Type of electrical connection of main circuit

Screw connection

With fuse

No

Degree of protection (NEMA)

Other

Supporting protocol for PROFIBUS

No

External reset possible

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for SafetyBUS p

No

Width

45mm

Supporting protocol for other bus systems

No

Depth

115mm

Height

180mm

Supporting protocol for CAN

No

Supporting protocol for INTERBUS

No

Supporting protocol for Modbus

No

Supporting protocol for ASI

No

Supporting protocol for Data-Highway

No

Supporting protocol for LON

No

Supporting protocol for DeviceNet

No

Supporting protocol for PROFINET IO

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SUCONET

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SERCOS

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DM-0,25-M7(230V50HZ)/MSFA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 400 V

0.06kW

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.04kW

Rated operation current at AC-3, 400 V

0.25A

Overload release current setting

0.16 .. 0.25A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

With short-circuit release

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

0.21A

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Voltage type for actuating

AC

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 2

Number of indicator lights

0

Number of command positions

0

Temperature compensated overload protection

Supporting protocol for TCP/IP

With transformer

Degree of protection (IP)

IP20

Release class

CLASS 10 A

Rail mounting possible

Suitable for emergency stop

Type of electrical connection of main circuit

Screw connection

With fuse

Degree of protection (NEMA)

Other

Supporting protocol for PROFIBUS

External reset possible

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Width

45mm

Supporting protocol for other bus systems

Depth

115mm

Height

180mm

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SUCONET

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.