Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP31
Type of control element
Push button
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
630A
Motor drive integrated
No
Overload release current setting
315 - 630A
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Yes
Type of electrical connection of main circuit
Rail connection
Rated voltage
690 - 690V
Number of auxiliary contacts as change-over contact
2
Adjustment range undelayed short-circuit release
1260 - 7560A
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range short-term delayed short-circuit release
1260 - 6300A
Position of connection for main current circuit
Back side
DIN rail (top hat rail) mounting optional
No
With under voltage release
No
Complete device with protection unit
Yes
Integrated earth fault protection
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
IZMX16N4-V06W-1

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP31
Type of control element
Push button
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
630A
Motor drive integrated
Overload release current setting
315 .. 630A
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Type of electrical connection of main circuit
Rail connection
Rated voltage
690 .. 690V
Number of auxiliary contacts as change-over contact
2
Adjustment range undelayed short-circuit release
1260 .. 7560A
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range short-term delayed short-circuit release
1260 .. 6300A
Position of connection for main current circuit
Back side
DIN rail (top hat rail) mounting optional
With under voltage release
Complete device with protection unit
Integrated earth fault protection
From same serie