Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP66
Width
161mm
Height
232mm
Depth
184mm
Degree of protection (NEMA)
4X
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFINET IO
No
Supporting protocol for ASI
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for KNX
No
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Supporting protocol for SERCOS
No
Supporting protocol for LON
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for Modbus
Yes
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
0
With optical interface
No
Number of HW-interfaces serial TTY
0
Number of analogue inputs
2
Number of analogue outputs
1
Number of digital inputs
4
Number of digital outputs
1
Nominal output current I2N
2.2A
With PC connection
Yes
With control element
Yes
4-quadrant operation possible
No
Application in domestic- and commercial area permitted
No
Integrated breaking resistance
No
Max. output frequency
500Hz
Max. output voltage
500V
Max. output at linear load at rated output voltage
0.75kW
Mains voltage
342 - 528V
Application in industrial area permitted
Yes
Type of converter
U converter
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
0.75kW
Number of phases input
3
Relative symmetric net frequency tolerance
10%
Number of phases output
3
Supporting protocol for BACnet
No
Mains frequency
50/60 Hz
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DC1-342D2NN-A6SCE1
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP66
Width
161mm
Height
232mm
Depth
184mm
Degree of protection (NEMA)
4X
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for PROFINET IO
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for other bus systems
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for KNX
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Supporting protocol for SERCOS
Supporting protocol for LON
Supporting protocol for EtherNet/IP
Supporting protocol for Modbus
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
0
With optical interface
Number of HW-interfaces serial TTY
0
Number of analogue inputs
2
Number of analogue outputs
1
Number of digital inputs
4
Number of digital outputs
1
Nominal output current I2N
2.2A
With PC connection
With control element
4-quadrant operation possible
Application in domestic- and commercial area permitted
Integrated breaking resistance
Max. output frequency
500Hz
Max. output voltage
500V
Max. output at linear load at rated output voltage
0.75kW
Mains voltage
342 .. 528V
Application in industrial area permitted
Type of converter
U converter
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
0.75kW
Number of phases input
3
Relative symmetric net frequency tolerance
10%
Number of phases output
3
Supporting protocol for BACnet
Mains frequency
50/60 Hz
From same serie
Related products
We use cookies to enhance your experience.