Aleta.hr
Main Product Image

DC1-342D2NN-A66CE1

Code: 1745770

ManufacturerRAZNO
Catalog number185722
Type
EAN code4015081812219

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP66

Width

161mm

Height

232mm

Depth

184mm

Degree of protection (NEMA)

4X

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SUCONET

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for DeviceNet

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for PROFINET IO

No

Supporting protocol for ASI

No

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

Yes

Supporting protocol for Data-Highway

No

Supporting protocol for INTERBUS

No

Supporting protocol for other bus systems

Yes

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for KNX

No

Number of interfaces PROFINET

0

Number of HW-interfaces USB

0

Supporting protocol for SERCOS

No

Supporting protocol for LON

No

Supporting protocol for EtherNet/IP

Yes

Supporting protocol for Modbus

Yes

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

0

With optical interface

No

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Number of analogue outputs

1

Number of digital inputs

4

Number of digital outputs

1

Nominal output current I2N

2.2A

With PC connection

Yes

With control element

Yes

4-quadrant operation possible

No

Application in domestic- and commercial area permitted

No

Integrated breaking resistance

No

Max. output frequency

500Hz

Max. output voltage

500V

Max. output at linear load at rated output voltage

0.75kW

Mains voltage

342 - 528V

Application in industrial area permitted

Yes

Type of converter

U converter

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

0.75kW

Number of phases input

3

Relative symmetric net frequency tolerance

10%

Number of phases output

3

Supporting protocol for BACnet

No

Mains frequency

50/60 Hz


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

DC1-342D2NN-A66CE1

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP66

Width

161mm

Height

232mm

Depth

184mm

Degree of protection (NEMA)

4X

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for SUCONET

Supporting protocol for DeviceNet Safety

Supporting protocol for DeviceNet

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for KNX

Number of interfaces PROFINET

0

Number of HW-interfaces USB

0

Supporting protocol for SERCOS

Supporting protocol for LON

Supporting protocol for EtherNet/IP

Supporting protocol for Modbus

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

0

With optical interface

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Number of analogue outputs

1

Number of digital inputs

4

Number of digital outputs

1

Nominal output current I2N

2.2A

With PC connection

With control element

4-quadrant operation possible

Application in domestic- and commercial area permitted

Integrated breaking resistance

Max. output frequency

500Hz

Max. output voltage

500V

Max. output at linear load at rated output voltage

0.75kW

Mains voltage

342 .. 528V

Application in industrial area permitted

Type of converter

U converter

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

0.75kW

Number of phases input

3

Relative symmetric net frequency tolerance

10%

Number of phases output

3

Supporting protocol for BACnet

Mains frequency

50/60 Hz

From same serie

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.