Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of phases output
3
Relative symmetric net frequency tolerance
10%
Max. output voltage
500V
Nominal output current I2N
2.2A
Mains voltage
380 - 480V
Max. output at quadratic load at rated output voltage
0.75kW
Max. output at linear load at rated output voltage
0.75kW
Number of phases input
3
Number of digital outputs
1
Max. output frequency
500Hz
Number of digital inputs
4
Application in industrial area permitted
Yes
Power consumption
63.75W
Mains frequency
50/60 Hz
Number of analogue outputs
1
With control element
Yes
Supporting protocol for CAN
Yes
Supporting protocol for Modbus
Yes
Supporting protocol for KNX
No
Number of analogue inputs
2
Supporting protocol for PROFIBUS
No
Supporting protocol for DeviceNet
No
Supporting protocol for TCP/IP
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Relative symmetric net voltage tolerance
10%
Supporting protocol for Data-Highway
No
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for INTERBUS
No
Number of HW-interfaces other
0
With PC connection
Yes
With optical interface
No
Supporting protocol for PROFIsafe
No
Number of HW-interfaces USB
0
Integrated breaking resistance
No
Type of converter
U converter
4-quadrant operation possible
No
Degree of protection (IP)
IP20
Supporting protocol for other bus systems
Yes
Supporting protocol for DeviceNet Safety
No
Supporting protocol for BACnet
No
Supporting protocol for EtherNet/IP
Yes
Degree of protection (NEMA)
Other
Height
184mm
Width
81mm
Supporting protocol for SafetyBUS p
No
Depth
124mm
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
No
Number of HW-interfaces parallel
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DC1-342D2NN-A20CE1

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of phases output
3
Relative symmetric net frequency tolerance
10%
Max. output voltage
500V
Nominal output current I2N
2.2A
Mains voltage
380 .. 480V
Max. output at quadratic load at rated output voltage
0.75kW
Max. output at linear load at rated output voltage
0.75kW
Number of phases input
3
Number of digital outputs
1
Max. output frequency
500Hz
Number of digital inputs
4
Application in industrial area permitted
Power consumption
63.75W
Mains frequency
50/60 Hz
Number of analogue outputs
1
With control element
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for KNX
Number of analogue inputs
2
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Supporting protocol for TCP/IP
Supporting protocol for LON
Supporting protocol for SERCOS
Relative symmetric net voltage tolerance
10%
Supporting protocol for Data-Highway
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for INTERBUS
Number of HW-interfaces other
0
With PC connection
With optical interface
Supporting protocol for PROFIsafe
Number of HW-interfaces USB
0
Integrated breaking resistance
Type of converter
U converter
4-quadrant operation possible
Degree of protection (IP)
IP20
Supporting protocol for other bus systems
Supporting protocol for DeviceNet Safety
Supporting protocol for BACnet
Supporting protocol for EtherNet/IP
Degree of protection (NEMA)
Other
Height
184mm
Width
81mm
Supporting protocol for SafetyBUS p
Depth
124mm
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
Number of HW-interfaces parallel
0
From same serie
Related products
We use cookies to enhance your experience.