- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains frequency
50/60 Hz
Mains voltage
380 - 480V
Number of phases input
3
Number of analogue outputs
1
Number of analogue inputs
2
Application in domestic- and commercial area permitted
Yes
Power consumption
728W
Max. output voltage
500V
Supporting protocol for PROFIBUS
No
Application in industrial area permitted
Yes
Supporting protocol for TCP/IP
No
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Max. output frequency
500Hz
Nominal output current I2N
39A
Number of digital outputs
1
Max. output at linear load at rated output voltage
18.5kW
Number of digital inputs
4
Relative symmetric net voltage tolerance
10%
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SUCONET
No
Max. output at quadratic load at rated output voltage
18.5kW
Supporting protocol for PROFINET IO
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for SafetyBUS p
No
Supporting protocol for LON
No
Supporting protocol for Data-Highway
No
With control element
Yes
Supporting protocol for other bus systems
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for BACnet
No
Supporting protocol for DeviceNet
No
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for SERCOS
No
Supporting protocol for CAN
Yes
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Supporting protocol for Modbus
Yes
Number of phases output
3
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Number of HW-interfaces serial TTY
0
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Supporting protocol for AS-Interface Safety at Work
No
Number of HW-interfaces parallel
0
Supporting protocol for KNX
No
Relative symmetric net frequency tolerance
10%
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
0
With optical interface
No
Integrated breaking resistance
Yes
With PC connection
Yes
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Height
418.5mm
Width
173mm
Depth
211mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DC1-34039NB-A20CE1

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains frequency
50/60 Hz
Mains voltage
380 .. 480V
Number of phases input
3
Number of analogue outputs
1
Number of analogue inputs
2
Application in domestic- and commercial area permitted
Power consumption
728W
Max. output voltage
500V
Supporting protocol for PROFIBUS
Application in industrial area permitted
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for INTERBUS
Max. output frequency
500Hz
Nominal output current I2N
39A
Number of digital outputs
1
Max. output at linear load at rated output voltage
18.5kW
Number of digital inputs
4
Relative symmetric net voltage tolerance
10%
Supporting protocol for DeviceNet Safety
Supporting protocol for SUCONET
Max. output at quadratic load at rated output voltage
18.5kW
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
Supporting protocol for LON
Supporting protocol for Data-Highway
With control element
Supporting protocol for other bus systems
Supporting protocol for PROFINET CBA
Supporting protocol for BACnet
Supporting protocol for DeviceNet
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for SERCOS
Supporting protocol for CAN
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Supporting protocol for Modbus
Number of phases output
3
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Number of HW-interfaces serial TTY
0
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Supporting protocol for AS-Interface Safety at Work
Number of HW-interfaces parallel
0
Supporting protocol for KNX
Relative symmetric net frequency tolerance
10%
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
0
With optical interface
Integrated breaking resistance
With PC connection
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Height
418.5mm
Width
173mm
Depth
211mm