Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
200 - 240V
Mains frequency
50/60 Hz
Power consumption
160W
Relative symmetric net frequency tolerance
10%
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
2
Number of analogue outputs
1
Number of phases output
3
Nominal output current I2N
15A
Max. output voltage
250V
Number of phases input
1
Supporting protocol for KNX
No
Supporting protocol for TCP/IP
No
Max. output at linear load at rated output voltage
4kW
Max. output frequency
500Hz
Supporting protocol for INTERBUS
No
With control element
Yes
Supporting protocol for DeviceNet
No
Supporting protocol for Modbus
Yes
Supporting protocol for PROFIBUS
No
Max. output at quadratic load at rated output voltage
4kW
Application in industrial area permitted
Yes
Supporting protocol for ASI
No
Number of digital inputs
4
Supporting protocol for CAN
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for Data-Highway
No
Number of digital outputs
1
Supporting protocol for SUCONET
No
Number of HW-interfaces other
0
With PC connection
Yes
Integrated breaking resistance
Yes
4-quadrant operation possible
Yes
Degree of protection (IP)
IP20
Type of converter
U converter
Height
273mm
Width
129mm
With optical interface
No
Depth
175mm
Degree of protection (NEMA)
Other
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for BACnet
No
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-232
0
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DC1-12015NB-A20CE1

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
200 .. 240V
Mains frequency
50/60 Hz
Power consumption
160W
Relative symmetric net frequency tolerance
10%
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
2
Number of analogue outputs
1
Number of phases output
3
Nominal output current I2N
15A
Max. output voltage
250V
Number of phases input
1
Supporting protocol for KNX
Supporting protocol for TCP/IP
Max. output at linear load at rated output voltage
4kW
Max. output frequency
500Hz
Supporting protocol for INTERBUS
With control element
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for PROFIBUS
Max. output at quadratic load at rated output voltage
4kW
Application in industrial area permitted
Supporting protocol for ASI
Number of digital inputs
4
Supporting protocol for CAN
Application in domestic- and commercial area permitted
Supporting protocol for Data-Highway
Number of digital outputs
1
Supporting protocol for SUCONET
Number of HW-interfaces other
0
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Degree of protection (IP)
IP20
Type of converter
U converter
Height
273mm
Width
129mm
With optical interface
Depth
175mm
Degree of protection (NEMA)
Other
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Supporting protocol for INTERBUS-Safety
Supporting protocol for BACnet
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-232
0
Supporting protocol for SafetyBUS p
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
0
From same serie
Related products
We use cookies to enhance your experience.