Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Height of sensor
65mm
Width sensor
31mm
Switching function
Quick-break switch
Switching function latching
No
Rated operation current Ie at DC-13, 230 V
0.27A
Output electronic
No
Rated operation current Ie at AC-15, 230 V
3A
Length of sensor
30mm
Number of safety auxiliary contacts
0
Forced opening
Yes
Number of contacts as normally closed contact
2
Number of contacts as normally open contact
0
Number of contacts as change-over contact
0
With status indication
No
Coating housing
Other
Type of electric connection
Connector M12
Material housing
Plastic
Explosion safety category for gas
None
Alignment of the control element
Other
Explosion safety category for dust
None
Type of control element
None
Suitable for safety functions
No
Type of interface
None
Construction type housing
Cuboid
Ambient temperature during operating
-25 - 70°C
Type of interface for safety communication
None
Degree of protection (IP)
IP66/IP67
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
Code: 1727988
ZCP29M12

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Height of sensor
65mm
Width sensor
31mm
Switching function
Quick-break switch
Switching function latching
Rated operation current Ie at DC-13, 230 V
0.27A
Output electronic
Rated operation current Ie at AC-15, 230 V
3A
Length of sensor
30mm
Number of safety auxiliary contacts
0
Forced opening
Number of contacts as normally closed contact
2
Number of contacts as normally open contact
0
Number of contacts as change-over contact
0
With status indication
Coating housing
Other
Type of electric connection
Connector M12
Material housing
Plastic
Explosion safety category for gas
None
Alignment of the control element
Other
Explosion safety category for dust
None
Type of control element
None
Suitable for safety functions
Type of interface
None
Construction type housing
Cuboid
Ambient temperature during operating
-25 .. 70°C
Type of interface for safety communication
None
Degree of protection (IP)
IP66/IP67
From same serie