- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Height of sensor
65mm
Length of sensor
30mm
Type of interface for safety communication
None
Material housing
Plastic
Number of contacts as normally open contact
1
Construction type housing
Cuboid
Number of contacts as normally closed contact
1
Coating housing
Other
Type of control element
None
Suitable for safety functions
No
With status indication
No
Rated operation current Ie at DC-13, 230 V
0.27A
Type of interface
None
Number of contacts as change-over contact
0
Alignment of the control element
Other
Explosion safety category for dust
None
Rated operation current Ie at AC-15, 230 V
3A
Forced opening
Yes
Output electronic
No
Switching function latching
No
Switching function
Quick-break switch
Number of safety auxiliary contacts
0
Explosion safety category for gas
None
Type of electric connection
Connector M12
Ambient temperature during operating
-25 - 70°C
Width sensor
31mm
Degree of protection (IP)
IP66/IP67
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCP21M12

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50047
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Height of sensor
65mm
Length of sensor
30mm
Type of interface for safety communication
None
Material housing
Plastic
Number of contacts as normally open contact
1
Construction type housing
Cuboid
Number of contacts as normally closed contact
1
Coating housing
Other
Type of control element
None
Suitable for safety functions
With status indication
Rated operation current Ie at DC-13, 230 V
0.27A
Type of interface
None
Number of contacts as change-over contact
0
Alignment of the control element
Other
Explosion safety category for dust
None
Rated operation current Ie at AC-15, 230 V
3A
Forced opening
Output electronic
Switching function latching
Switching function
Quick-break switch
Number of safety auxiliary contacts
0
Explosion safety category for gas
None
Type of electric connection
Connector M12
Ambient temperature during operating
-25 .. 70°C
Width sensor
31mm
Degree of protection (IP)
IP66/IP67