Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
Other
Diameter sensor
0mm
Width sensor
30mm
Rated operation current Ie at AC-15, 24 V
0A
Length of sensor
16mm
Output electronic
No
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at DC-13, 230 V
0.1A
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 125 V
0A
Number of safety auxiliary contacts
0
Number of contacts as normally open contact
1
Switching function latching
No
Number of contacts as normally closed contact
2
Type of interface
None
Construction type housing
Cuboid
Coating housing
Other
Alignment of the control element
Other
Type of interface for safety communication
None
Number of contacts as change-over contact
0
Material housing
Metal
Height of sensor
52mm
Rated operation current Ie at DC-13, 125 V
0A
Forced opening
Yes
Type of control element
None
Explosion safety category for gas
None
Suitable for safety functions
No
Explosion safety category for dust
None
Degree of protection (IP)
IP66
Ambient temperature during operating
-25 - 70°C
With status indication
No
Type of electric connection
With cable preassembled
From same serie
ZCMD39L1

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
Other
Diameter sensor
0mm
Width sensor
30mm
Rated operation current Ie at AC-15, 24 V
0A
Length of sensor
16mm
Output electronic
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at DC-13, 230 V
0.1A
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 125 V
0A
Number of safety auxiliary contacts
0
Number of contacts as normally open contact
1
Switching function latching
Number of contacts as normally closed contact
2
Type of interface
None
Construction type housing
Cuboid
Coating housing
Other
Alignment of the control element
Other
Type of interface for safety communication
None
Number of contacts as change-over contact
0
Material housing
Metal
Height of sensor
52mm
Rated operation current Ie at DC-13, 125 V
0A
Forced opening
Type of control element
None
Explosion safety category for gas
None
Suitable for safety functions
Explosion safety category for dust
None
Degree of protection (IP)
IP66
Ambient temperature during operating
-25 .. 70°C
With status indication
Type of electric connection
With cable preassembled
From same serie
We use cookies to enhance your experience.