- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Height of sensor
52mm
Forced opening
Yes
Number of contacts as normally closed contact
2
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Type of interface for safety communication
None
Diameter sensor
0mm
Width sensor
30mm
Rated operation current Ie at DC-13, 230 V
0.1A
Output electronic
No
Type of interface
None
Rated operation current Ie at AC-15, 230 V
1.5A
Number of contacts as change-over contact
0
Switching function latching
No
Switching function
Slow-action switch
Length of sensor
16mm
Type of control element
None
Suitable for safety functions
No
Explosion safety category for dust
None
Construction type housing
Cuboid
Alignment of the control element
Other
Coating housing
Other
Material housing
Metal
Number of safety auxiliary contacts
0
Type of electric connection
With cable preassembled
Explosion safety category for gas
None
Number of contacts as normally open contact
1
With status indication
No
Ambient temperature during operating
-25 - 70°C
Degree of protection (IP)
IP66
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCMD37L5

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
Other
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Height of sensor
52mm
Forced opening
Number of contacts as normally closed contact
2
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Type of interface for safety communication
None
Diameter sensor
0mm
Width sensor
30mm
Rated operation current Ie at DC-13, 230 V
0.1A
Output electronic
Type of interface
None
Rated operation current Ie at AC-15, 230 V
1.5A
Number of contacts as change-over contact
0
Switching function latching
Switching function
Slow-action switch
Length of sensor
16mm
Type of control element
None
Suitable for safety functions
Explosion safety category for dust
None
Construction type housing
Cuboid
Alignment of the control element
Other
Coating housing
Other
Material housing
Metal
Number of safety auxiliary contacts
0
Type of electric connection
With cable preassembled
Explosion safety category for gas
None
Number of contacts as normally open contact
1
With status indication
Ambient temperature during operating
-25 .. 70°C
Degree of protection (IP)
IP66