Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Width sensor
40mm
Rated operation current Ie at DC-13, 24 V
0A
Forced opening
Yes
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Length of sensor
36mm
Height of sensor
73mm
Diameter sensor
0mm
Output electronic
No
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 24 V
0A
Switching function latching
No
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as change-over contact
0
Number of contacts as normally closed contact
2
Construction type housing
Cuboid
Type of interface for safety communication
None
Material housing
Plastic
Coating housing
Other
With status indication
No
Type of interface
None
Type of electric connection
Cable entry PG
Number of contacts as normally open contact
0
Suitable for safety functions
No
Type of control element
None
Number of safety auxiliary contacts
0
Alignment of the control element
Other
Explosion safety category for dust
None
Ambient temperature during operating
-25 - 70°C
Explosion safety category for gas
None
Degree of protection (IP)
IP65
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCKS9

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Width sensor
40mm
Rated operation current Ie at DC-13, 24 V
0A
Forced opening
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Length of sensor
36mm
Height of sensor
73mm
Diameter sensor
0mm
Output electronic
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 24 V
0A
Switching function latching
Rated operation current Ie at AC-15, 230 V
3A
Number of contacts as change-over contact
0
Number of contacts as normally closed contact
2
Construction type housing
Cuboid
Type of interface for safety communication
None
Material housing
Plastic
Coating housing
Other
With status indication
Type of interface
None
Type of electric connection
Cable entry PG
Number of contacts as normally open contact
0
Suitable for safety functions
Type of control element
None
Number of safety auxiliary contacts
0
Alignment of the control element
Other
Explosion safety category for dust
None
Ambient temperature during operating
-25 .. 70°C
Explosion safety category for gas
None
Degree of protection (IP)
IP65
From same serie
We use cookies to enhance your experience.