Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Diameter sensor
0mm
Length of sensor
44mm
Width sensor
40mm
Rated operation current Ie at DC-13, 24 V
0A
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 125 V
0A
Output electronic
No
Number of contacts as change-over contact
0
Number of contacts as normally open contact
2
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.1A
Rated operation current Ie at AC-15, 24 V
0A
Number of contacts as normally closed contact
1
Switching function latching
No
Rated operation current Ie at AC-15, 230 V
1.5A
Height of sensor
77mm
Forced opening
Yes
Number of safety auxiliary contacts
0
Type of interface
None
Material housing
Metal
Alignment of the control element
Other
Type of interface for safety communication
None
Coating housing
Other
Type of control element
None
Construction type housing
Cuboid
With status indication
No
Degree of protection (IP)
IP65
Type of electric connection
Cable entry metrical
Explosion safety category for gas
None
Explosion safety category for dust
None
Suitable for safety functions
No
Ambient temperature during operating
-25 - 70°C
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCKJD31H29

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Diameter sensor
0mm
Length of sensor
44mm
Width sensor
40mm
Rated operation current Ie at DC-13, 24 V
0A
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 125 V
0A
Output electronic
Number of contacts as change-over contact
0
Number of contacts as normally open contact
2
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.1A
Rated operation current Ie at AC-15, 24 V
0A
Number of contacts as normally closed contact
1
Switching function latching
Rated operation current Ie at AC-15, 230 V
1.5A
Height of sensor
77mm
Forced opening
Number of safety auxiliary contacts
0
Type of interface
None
Material housing
Metal
Alignment of the control element
Other
Type of interface for safety communication
None
Coating housing
Other
Type of control element
None
Construction type housing
Cuboid
With status indication
Degree of protection (IP)
IP65
Type of electric connection
Cable entry metrical
Explosion safety category for gas
None
Explosion safety category for dust
None
Suitable for safety functions
Ambient temperature during operating
-25 .. 70°C
From same serie