Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Length of sensor
44mm
Diameter sensor
0mm
Width sensor
40mm
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Output electronic
No
Forced opening
Yes
Number of contacts as normally open contact
0
Construction type housing
Cuboid
Type of control element
None
Alignment of the control element
Other
Suitable for safety functions
No
With status indication
No
Explosion safety category for dust
None
Degree of protection (IP)
IP65
Number of contacts as normally closed contact
2
Switching function latching
No
Switching function
Quick-break switch
Explosion safety category for gas
None
Number of safety auxiliary contacts
0
Rated operation current Ie at DC-13, 125 V
0A
Number of contacts as change-over contact
0
Height of sensor
77mm
Type of interface
None
Ambient temperature during operating
-25 - 70°C
Type of electric connection
Cable entry PG
Rated operation current Ie at DC-13, 24 V
0A
Coating housing
Other
Type of interface for safety communication
None
Material housing
Metal
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCKJ9

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Length of sensor
44mm
Diameter sensor
0mm
Width sensor
40mm
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Output electronic
Forced opening
Number of contacts as normally open contact
0
Construction type housing
Cuboid
Type of control element
None
Alignment of the control element
Other
Suitable for safety functions
With status indication
Explosion safety category for dust
None
Degree of protection (IP)
IP65
Number of contacts as normally closed contact
2
Switching function latching
Switching function
Quick-break switch
Explosion safety category for gas
None
Number of safety auxiliary contacts
0
Rated operation current Ie at DC-13, 125 V
0A
Number of contacts as change-over contact
0
Height of sensor
77mm
Type of interface
None
Ambient temperature during operating
-25 .. 70°C
Type of electric connection
Cable entry PG
Rated operation current Ie at DC-13, 24 V
0A
Coating housing
Other
Type of interface for safety communication
None
Material housing
Metal
From same serie