Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Number of contacts as change-over contact
2
Rated operation current Ie at AC-15, 125 V
0A
Number of contacts as normally open contact
0
Type of interface
None
Construction type housing
Cuboid
Switching function
Quick-break switch
Height of sensor
102mm
Switching function latching
No
Type of control element
None
Type of interface for safety communication
None
Coating housing
Other
Rated operation current Ie at DC-13, 230 V
0.27A
Output electronic
No
Diameter sensor
0mm
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
0
Rated operation current Ie at DC-13, 125 V
0A
Length of sensor
60mm
Rated operation current Ie at AC-15, 230 V
3A
Forced opening
No
Width sensor
40mm
Alignment of the control element
Other
Material housing
Metal
Explosion safety category for dust
None
Type of electric connection
Cable entry PG
Suitable for safety functions
No
Explosion safety category for gas
None
Degree of protection (IP)
IP65
Ambient temperature during operating
-25 - 70°C
With status indication
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCKJ404

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Number of contacts as change-over contact
2
Rated operation current Ie at AC-15, 125 V
0A
Number of contacts as normally open contact
0
Type of interface
None
Construction type housing
Cuboid
Switching function
Quick-break switch
Height of sensor
102mm
Switching function latching
Type of control element
None
Type of interface for safety communication
None
Coating housing
Other
Rated operation current Ie at DC-13, 230 V
0.27A
Output electronic
Diameter sensor
0mm
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
0
Rated operation current Ie at DC-13, 125 V
0A
Length of sensor
60mm
Rated operation current Ie at AC-15, 230 V
3A
Forced opening
Width sensor
40mm
Alignment of the control element
Other
Material housing
Metal
Explosion safety category for dust
None
Type of electric connection
Cable entry PG
Suitable for safety functions
Explosion safety category for gas
None
Degree of protection (IP)
IP65
Ambient temperature during operating
-25 .. 70°C
With status indication
From same serie
We use cookies to enhance your experience.