Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Diameter sensor
0mm
Length of sensor
36mm
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at DC-13, 24 V
0A
Number of contacts as change-over contact
1
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
0
Alignment of the control element
Other
Switching function latching
No
Type of electric connection
Cable entry metrical
Forced opening
No
Degree of protection (IP)
IP65
Width sensor
43mm
Type of interface for safety communication
None
Height of sensor
84mm
Output electronic
No
Suitable for safety functions
No
Construction type housing
Cuboid
With status indication
No
Explosion safety category for dust
None
Ambient temperature during operating
20 - 120°C
Explosion safety category for gas
None
Type of interface
None
Number of contacts as normally open contact
0
Type of control element
None
Switching function
Quick-break switch
Material housing
Metal
Coating housing
Other
Rated operation current Ie at AC-15, 24 V
0A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCKJ115H29

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Diameter sensor
0mm
Length of sensor
36mm
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 230 V
0.27A
Rated operation current Ie at DC-13, 24 V
0A
Number of contacts as change-over contact
1
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
0
Alignment of the control element
Other
Switching function latching
Type of electric connection
Cable entry metrical
Forced opening
Degree of protection (IP)
IP65
Width sensor
43mm
Type of interface for safety communication
None
Height of sensor
84mm
Output electronic
Suitable for safety functions
Construction type housing
Cuboid
With status indication
Explosion safety category for dust
None
Ambient temperature during operating
20 .. 120°C
Explosion safety category for gas
None
Type of interface
None
Number of contacts as normally open contact
0
Type of control element
None
Switching function
Quick-break switch
Material housing
Metal
Coating housing
Other
Rated operation current Ie at AC-15, 24 V
0A
From same serie