Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Forced opening
No
Switching function latching
No
Output electronic
No
Height of sensor
84mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Construction type housing
Cuboid
Rated operation current Ie at DC-13, 230 V
0.27A
Number of contacts as normally open contact
0
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
0
Diameter sensor
0mm
Type of electric connection
Cable entry PG
Explosion safety category for dust
None
Type of interface
None
With status indication
No
Coating housing
Other
Type of control element
None
Number of contacts as change-over contact
1
Switching function
Quick-break switch
Explosion safety category for gas
None
Material housing
Metal
Length of sensor
36mm
Width sensor
43mm
Rated operation current Ie at AC-15, 230 V
3A
Alignment of the control element
Other
Type of interface for safety communication
None
Ambient temperature during operating
-25 - 70°C
Suitable for safety functions
No
Degree of protection (IP)
IP65
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCKJ11

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50041
Rated operation current Ie at DC-13, 125 V
0A
Forced opening
Switching function latching
Output electronic
Height of sensor
84mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 24 V
0A
Construction type housing
Cuboid
Rated operation current Ie at DC-13, 230 V
0.27A
Number of contacts as normally open contact
0
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
0
Diameter sensor
0mm
Type of electric connection
Cable entry PG
Explosion safety category for dust
None
Type of interface
None
With status indication
Coating housing
Other
Type of control element
None
Number of contacts as change-over contact
1
Switching function
Quick-break switch
Explosion safety category for gas
None
Material housing
Metal
Length of sensor
36mm
Width sensor
43mm
Rated operation current Ie at AC-15, 230 V
3A
Alignment of the control element
Other
Type of interface for safety communication
None
Ambient temperature during operating
-25 .. 70°C
Suitable for safety functions
Degree of protection (IP)
IP65
From same serie
We use cookies to enhance your experience.