Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50047
Height of sensor
65mm
Rated operation current Ie at AC-15, 230 V
0.75A
Rated operation current Ie at DC-13, 24 V
0A
Output electronic
No
Switching function
Quick-break switch
Switching function latching
No
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
1
Rated operation current Ie at AC-15, 125 V
0A
Forced opening
Yes
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
31mm
Rated operation current Ie at DC-13, 230 V
0.1A
Length of sensor
30mm
Number of contacts as change-over contact
0
Diameter sensor
0mm
Alignment of the control element
Other
Type of control element
None
Number of contacts as normally open contact
0
Type of interface
None
With status indication
No
Type of interface for safety communication
None
Construction type housing
Cuboid
Suitable for safety functions
No
Explosion safety category for dust
None
Ambient temperature during operating
-25 - 70°C
Degree of protection (IP)
IP66/IP67
Type of electric connection
Other
Coating housing
Other
Material housing
Metal
Explosion safety category for gas
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCD67

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50047
Height of sensor
65mm
Rated operation current Ie at AC-15, 230 V
0.75A
Rated operation current Ie at DC-13, 24 V
0A
Output electronic
Switching function
Quick-break switch
Switching function latching
Number of safety auxiliary contacts
0
Number of contacts as normally closed contact
1
Rated operation current Ie at AC-15, 125 V
0A
Forced opening
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Width sensor
31mm
Rated operation current Ie at DC-13, 230 V
0.1A
Length of sensor
30mm
Number of contacts as change-over contact
0
Diameter sensor
0mm
Alignment of the control element
Other
Type of control element
None
Number of contacts as normally open contact
0
Type of interface
None
With status indication
Type of interface for safety communication
None
Construction type housing
Cuboid
Suitable for safety functions
Explosion safety category for dust
None
Ambient temperature during operating
-25 .. 70°C
Degree of protection (IP)
IP66/IP67
Type of electric connection
Other
Coating housing
Other
Material housing
Metal
Explosion safety category for gas
Other