Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50047
Height of sensor
65mm
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 230 V
0.1A
Switching function
Quick-break switch
Rated operation current Ie at DC-13, 125 V
0A
Output electronic
No
Length of sensor
30mm
Width sensor
31mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Diameter sensor
0mm
Number of safety auxiliary contacts
0
Forced opening
Yes
Number of contacts as normally closed contact
2
Switching function latching
No
Number of contacts as normally open contact
0
Material housing
Metal
Coating housing
Other
Number of contacts as change-over contact
0
Construction type housing
Cuboid
Type of control element
None
Type of interface
None
Type of interface for safety communication
None
Alignment of the control element
Other
Explosion safety category for gas
Other
Explosion safety category for dust
None
Ambient temperature during operating
-25 - 70°C
Degree of protection (IP)
IP66/IP67
With status indication
No
Suitable for safety functions
No
Type of electric connection
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCD29

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50047
Height of sensor
65mm
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at DC-13, 230 V
0.1A
Switching function
Quick-break switch
Rated operation current Ie at DC-13, 125 V
0A
Output electronic
Length of sensor
30mm
Width sensor
31mm
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Diameter sensor
0mm
Number of safety auxiliary contacts
0
Forced opening
Number of contacts as normally closed contact
2
Switching function latching
Number of contacts as normally open contact
0
Material housing
Metal
Coating housing
Other
Number of contacts as change-over contact
0
Construction type housing
Cuboid
Type of control element
None
Type of interface
None
Type of interface for safety communication
None
Alignment of the control element
Other
Explosion safety category for gas
Other
Explosion safety category for dust
None
Ambient temperature during operating
-25 .. 70°C
Degree of protection (IP)
IP66/IP67
With status indication
Suitable for safety functions
Type of electric connection
Other
From same serie