Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50047
Number of safety auxiliary contacts
0
Height of sensor
65mm
Width sensor
31mm
Forced opening
No
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Number of contacts as normally closed contact
0
Switching function
Slow-action switch with overlapping
Rated operation current Ie at DC-13, 24 V
0A
Type of interface for safety communication
None
Length of sensor
30mm
Output electronic
No
Switching function latching
No
Rated operation current Ie at DC-13, 230 V
0.1A
Number of contacts as change-over contact
0
Number of contacts as normally open contact
2
Type of electric connection
Other
Diameter sensor
0mm
Material housing
Metal
Coating housing
Other
Type of interface
None
Ambient temperature during operating
-25 - 70°C
Degree of protection (IP)
IP66/IP67
Construction type housing
Cuboid
Alignment of the control element
Other
With status indication
No
Explosion safety category for gas
Other
Suitable for safety functions
No
Explosion safety category for dust
None
Type of control element
None
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCD28

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
DIN EN 50047
Number of safety auxiliary contacts
0
Height of sensor
65mm
Width sensor
31mm
Forced opening
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Number of contacts as normally closed contact
0
Switching function
Slow-action switch with overlapping
Rated operation current Ie at DC-13, 24 V
0A
Type of interface for safety communication
None
Length of sensor
30mm
Output electronic
Switching function latching
Rated operation current Ie at DC-13, 230 V
0.1A
Number of contacts as change-over contact
0
Number of contacts as normally open contact
2
Type of electric connection
Other
Diameter sensor
0mm
Material housing
Metal
Coating housing
Other
Type of interface
None
Ambient temperature during operating
-25 .. 70°C
Degree of protection (IP)
IP66/IP67
Construction type housing
Cuboid
Alignment of the control element
Other
With status indication
Explosion safety category for gas
Other
Suitable for safety functions
Explosion safety category for dust
None
Type of control element
None
From same serie