Details
- Sensors
- Fork light barrier
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Diameter sensor
-mm
Transmission range of the safety field
-m
Switching voltage of OSSD at state "high"
-V
Wavelength of the sensor
-nm
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Rated switching distance
5mm
With time function
No
Max. output current
100mA
Min. object size
0.2mm
Max. switching distance
5mm
Setting procedure
Other
With reflector
No
Analogue output 0 V ... 10 V
No
Fork width
5mm
Fork depth
42mm
Analogue output -10 V ... +10 V
No
Analogue output 0 mA ... 20 mA
No
Analogue output 4 mA ... 20 mA
No
With communication interface analogue
No
With other analogue output
No
With communication interface SSD
No
With communication interface RS-422
No
With communication interface RS-485
No
With communication interface SSI
No
Number of contact energized outputs with signalling function
0
With communication interface RS-232
No
Explosion safety category for gas
None
Number of protected semiconductor outputs
0
Type of interface for safety communication
Other
Height of sensor
42mm
Type of switch function
Programmable/configurable
Pre failure notice
No
Laser protection class
None
Material of cable sheath
Other
Type of light
Other
With restart blockage
No
With communication interface DeviceNet
No
Suitable for safety functions
No
Degree of protection (IP)
IP65
Rated control supply voltage Us at DC
12 - 24V
With communication interface CANOpen
No
Explosion safety category for dust
None
Length of sensor
10mm
With communication interface INTERBUS
No
Ambient temperature
-20 - 60°C
Type of switching output
PNP/NPN
With communication interface PROFIBUS
No
Construction type housing
Special construction
Response time
0.02ms
Sensing mode
Light switching
Voltage type
AC/DC
Material housing
Metal
Number of semiconductor outputs with signalling function
0
Type of safety according to IEC 61496-1
1
Number of protected contact energized outputs
0
With communication interface Ethernet
No
With communication interface AS-Interface
No
Operation agent-safety class
Safety class 0
Material of optical surface
Glass
Width sensor
5mm
Type of electric connection
Connector M8
Switching frequency
10000Hz
Max. output current at protected output
100mA
With monitoring function downstream switching devices
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUYFANEP40005

Details
- Sensors
- Fork light barrier
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Diameter sensor
-mm
Transmission range of the safety field
-m
Switching voltage of OSSD at state "high"
-V
Wavelength of the sensor
-nm
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Rated switching distance
5mm
With time function
Max. output current
100mA
Min. object size
0.2mm
Max. switching distance
5mm
Setting procedure
Other
With reflector
Analogue output 0 V ... 10 V
Fork width
5mm
Fork depth
42mm
Analogue output -10 V ... +10 V
Analogue output 0 mA ... 20 mA
Analogue output 4 mA ... 20 mA
With communication interface analogue
With other analogue output
With communication interface SSD
With communication interface RS-422
With communication interface RS-485
With communication interface SSI
Number of contact energized outputs with signalling function
0
With communication interface RS-232
Explosion safety category for gas
None
Number of protected semiconductor outputs
0
Type of interface for safety communication
Other
Height of sensor
42mm
Type of switch function
Programmable/configurable
Pre failure notice
Laser protection class
None
Material of cable sheath
Other
Type of light
Other
With restart blockage
With communication interface DeviceNet
Suitable for safety functions
Degree of protection (IP)
IP65
Rated control supply voltage Us at DC
12 .. 24V
With communication interface CANOpen
Explosion safety category for dust
None
Length of sensor
10mm
With communication interface INTERBUS
Ambient temperature
-20 .. 60°C
Type of switching output
PNP/NPN
With communication interface PROFIBUS
Construction type housing
Special construction
Response time
0.02ms
Sensing mode
Light switching
Voltage type
AC/DC
Material housing
Metal
Number of semiconductor outputs with signalling function
0
Type of safety according to IEC 61496-1
1
Number of protected contact energized outputs
0
With communication interface Ethernet
With communication interface AS-Interface
Operation agent-safety class
Safety class 0
Material of optical surface
Glass
Width sensor
5mm
Type of electric connection
Connector M8
Switching frequency
10000Hz
Max. output current at protected output
100mA
With monitoring function downstream switching devices
From same serie