Aleta.hr
Main Product Image

XUVF60M8

Code: 1723245

ManufacturerRAZNO
Catalog numberXUVF60M8
Type
EAN code3389110168884

Details

  • Sensors
  • Optical frame sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Max. switching distance

-mm

Min. reflector distance

-mm

Light dot

-mm²

Rated switching distance

-mm

AWG-number

-

Max. output current

100mA

Frame opening lengthwise

60mm

Min. object size

2mm

Frame opening cross

60mm

Pre failure notice

No

Laser protection class

None

Material of cable sheath

Other

Type of light

Infrared light

Number of protected contact energized outputs

0

With time function

Yes

Number of contact energized outputs with signalling function

0

With communication interface SSI

No

With communication interface SSD

No

Number of protected semiconductor outputs

1

Type of switch function

Programmable/configurable

Explosion safety category for dust

None

Max. output current at protected output

100mA

Response time

1ms

Voltage type

AC/DC

Analogue output -10 V ... +10 V

No

Type of interface for safety communication

Other

Width sensor

131mm

Type of switching output

PNP/NPN

Operation agent-safety class

Safety class 0

Length of sensor

15mm

Height of sensor

86mm

Material housing

Metal

Type of safety according to IEC 61496-1

1

Explosion safety category for gas

None

Analogue output 0 V ... 10 V

No

Ambient temperature

0 - 60°C

Material of optical surface

Plastic

Switching frequency

500Hz

Analogue output 4 mA ... 20 mA

No

With communication interface CANOpen

No

Setting procedure

Manual adjustment

Construction type housing

Special construction

With communication interface INTERBUS

No

With reflector

No

With other analogue output

No

Number of semiconductor outputs with signalling function

1

Rated control supply voltage Us at DC

24 - 24V

Sensing mode

Dark switching

Analogue output 0 mA ... 20 mA

No

With communication interface RS-485

No

With communication interface DeviceNet

No

With communication interface AS-Interface

No

With communication interface RS-422

No

With communication interface PROFIBUS

No

With communication interface RS-232

No

With restart blockage

No

Suitable for safety functions

No

Degree of protection (IP)

IP65

Type of electric connection

Connector M8

With monitoring function downstream switching devices

No

With communication interface analogue

No

With communication interface Ethernet

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUVF60M8

Main Product Image

Details

  • Sensors
  • Optical frame sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Max. switching distance

-mm

Min. reflector distance

-mm

Light dot

-mm²

Rated switching distance

-mm

AWG-number

-

Max. output current

100mA

Frame opening lengthwise

60mm

Min. object size

2mm

Frame opening cross

60mm

Pre failure notice

Laser protection class

None

Material of cable sheath

Other

Type of light

Infrared light

Number of protected contact energized outputs

0

With time function

Number of contact energized outputs with signalling function

0

With communication interface SSI

With communication interface SSD

Number of protected semiconductor outputs

1

Type of switch function

Programmable/configurable

Explosion safety category for dust

None

Max. output current at protected output

100mA

Response time

1ms

Voltage type

AC/DC

Analogue output -10 V ... +10 V

Type of interface for safety communication

Other

Width sensor

131mm

Type of switching output

PNP/NPN

Operation agent-safety class

Safety class 0

Length of sensor

15mm

Height of sensor

86mm

Material housing

Metal

Type of safety according to IEC 61496-1

1

Explosion safety category for gas

None

Analogue output 0 V ... 10 V

Ambient temperature

0 .. 60°C

Material of optical surface

Plastic

Switching frequency

500Hz

Analogue output 4 mA ... 20 mA

With communication interface CANOpen

Setting procedure

Manual adjustment

Construction type housing

Special construction

With communication interface INTERBUS

With reflector

With other analogue output

Number of semiconductor outputs with signalling function

1

Rated control supply voltage Us at DC

24 .. 24V

Sensing mode

Dark switching

Analogue output 0 mA ... 20 mA

With communication interface RS-485

With communication interface DeviceNet

With communication interface AS-Interface

With communication interface RS-422

With communication interface PROFIBUS

With communication interface RS-232

With restart blockage

Suitable for safety functions

Degree of protection (IP)

IP65

Type of electric connection

Connector M8

With monitoring function downstream switching devices

With communication interface analogue

With communication interface Ethernet

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.