Aleta.hr

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Diameter sensor

-mm

Transmission range of the safety field

-m

Switching voltage of OSSD at state "high"

-V

Wavelength of the sensor

-nm

Light dot

-mm²

Pre failure notice

No

Max. switching distance

70000mm

Max. output current

100mA

Rated switching distance

70000mm

Analogue output -10 V ... +10 V

No

With other analogue output

No

With communication interface analogue

No

Analogue output 0 V ... 10 V

No

With reflector

No

With communication interface RS-422

No

With time function

No

With communication interface PROFIBUS

No

With communication interface CANOpen

No

With communication interface RS-485

No

With communication interface AS-Interface

No

With communication interface SSD

No

Analogue output 0 mA ... 20 mA

No

Analogue output 4 mA ... 20 mA

Yes

With communication interface DeviceNet

No

With communication interface INTERBUS

No

With communication interface RS-232

No

Setting procedure

Teach-In

With communication interface Ethernet

No

Number of contact energized outputs with signalling function

0

Number of semiconductor outputs with signalling function

2

Type of electric connection

Connector M12

Explosion safety category for gas

None

Operation agent-safety class

Safety class 0

Type of switching output

PNP/NPN

Construction type housing

Cuboid

Length of sensor

50mm

Width sensor

18mm

Height of sensor

50mm

Material of optical surface

Plastic

Type of interface for safety communication

Other

Sensing mode

Light-/dark switching

Number of protected semiconductor outputs

2

Min. reflector distance

300mm

Type of switch function

Programmable/configurable

Material housing

Plastic

With communication interface SSI

No

Number of protected contact energized outputs

0

Explosion safety category for dust

None

With monitoring function downstream switching devices

No

With restart blockage

No

Type of light

Laser diode, red light

Laser protection class

Class 1

Suitable for safety functions

No

Degree of protection (IP)

IP67K

Ambient temperature

-10 - 60°C

Max. output current at protected output

100mA

Rated control supply voltage Us at DC

24 - 24V

Switching frequency

2000Hz

Type of safety according to IEC 61496-1

1

Response time

2ms

Voltage type

AC/DC


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUK9TAH2MM12

Main Product Image

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Diameter sensor

-mm

Transmission range of the safety field

-m

Switching voltage of OSSD at state "high"

-V

Wavelength of the sensor

-nm

Light dot

-mm²

Pre failure notice

Max. switching distance

70000mm

Max. output current

100mA

Rated switching distance

70000mm

Analogue output -10 V ... +10 V

With other analogue output

With communication interface analogue

Analogue output 0 V ... 10 V

With reflector

With communication interface RS-422

With time function

With communication interface PROFIBUS

With communication interface CANOpen

With communication interface RS-485

With communication interface AS-Interface

With communication interface SSD

Analogue output 0 mA ... 20 mA

Analogue output 4 mA ... 20 mA

With communication interface DeviceNet

With communication interface INTERBUS

With communication interface RS-232

Setting procedure

Teach-In

With communication interface Ethernet

Number of contact energized outputs with signalling function

0

Number of semiconductor outputs with signalling function

2

Type of electric connection

Connector M12

Explosion safety category for gas

None

Operation agent-safety class

Safety class 0

Type of switching output

PNP/NPN

Construction type housing

Cuboid

Length of sensor

50mm

Width sensor

18mm

Height of sensor

50mm

Material of optical surface

Plastic

Type of interface for safety communication

Other

Sensing mode

Light-/dark switching

Number of protected semiconductor outputs

2

Min. reflector distance

300mm

Type of switch function

Programmable/configurable

Material housing

Plastic

With communication interface SSI

Number of protected contact energized outputs

0

Explosion safety category for dust

None

With monitoring function downstream switching devices

With restart blockage

Type of light

Laser diode, red light

Laser protection class

Class 1

Suitable for safety functions

Degree of protection (IP)

IP67K

Ambient temperature

-10 .. 60°C

Max. output current at protected output

100mA

Rated control supply voltage Us at DC

24 .. 24V

Switching frequency

2000Hz

Type of safety according to IEC 61496-1

1

Response time

2ms

Voltage type

AC/DC

From same serie