Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Diameter sensor
-mm
Transmission range of the safety field
-m
Switching voltage of OSSD at state "high"
-V
Wavelength of the sensor
-nm
Light dot
-mm²
Pre failure notice
No
With time function
No
Rated switching distance
5000mm
Max. output current
100mA
With other analogue output
No
Analogue output -10 V ... +10 V
No
Max. switching distance
8000mm
With communication interface PROFIBUS
No
Setting procedure
Other
With communication interface Ethernet
No
With communication interface RS-485
No
With communication interface AS-Interface
No
Analogue output 0 V ... 10 V
No
With communication interface SSI
No
Type of electric connection
Cable radial
Type of interface for safety communication
Other
Type of switch function
Breaker contact (NC)
Explosion safety category for gas
None
Number of protected semiconductor outputs
1
Sensing mode
Light-/dark switching
Material housing
Plastic
Operation agent-safety class
Safety class 0
Response time
2ms
Height of sensor
50mm
Width sensor
18mm
Material of optical surface
Plastic
Length of sensor
50mm
Analogue output 4 mA ... 20 mA
No
Number of semiconductor outputs with signalling function
1
With communication interface RS-422
No
With communication interface analogue
No
With communication interface CANOpen
No
With communication interface SSD
No
Type of switching output
PNP/PNP
With communication interface DeviceNet
No
With reflector
No
With communication interface RS-232
No
Number of protected contact energized outputs
0
With communication interface INTERBUS
No
Explosion safety category for dust
None
Number of contact energized outputs with signalling function
0
Analogue output 0 mA ... 20 mA
No
With monitoring function downstream switching devices
No
Laser protection class
None
Type of light
Polarized red light
Switching frequency
250Hz
Suitable for safety functions
No
Degree of protection (IP)
IP65
With restart blockage
No
Max. output current at protected output
100mA
Min. reflector distance
1000mm
Type of safety according to IEC 61496-1
1
Construction type housing
Cuboid
Voltage type
AC/DC
Rated control supply voltage Us at DC
12 - 24V
Ambient temperature
-25 - 55°C
From same serie
XUK9APBNL2

Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Diameter sensor
-mm
Transmission range of the safety field
-m
Switching voltage of OSSD at state "high"
-V
Wavelength of the sensor
-nm
Light dot
-mm²
Pre failure notice
With time function
Rated switching distance
5000mm
Max. output current
100mA
With other analogue output
Analogue output -10 V ... +10 V
Max. switching distance
8000mm
With communication interface PROFIBUS
Setting procedure
Other
With communication interface Ethernet
With communication interface RS-485
With communication interface AS-Interface
Analogue output 0 V ... 10 V
With communication interface SSI
Type of electric connection
Cable radial
Type of interface for safety communication
Other
Type of switch function
Breaker contact (NC)
Explosion safety category for gas
None
Number of protected semiconductor outputs
1
Sensing mode
Light-/dark switching
Material housing
Plastic
Operation agent-safety class
Safety class 0
Response time
2ms
Height of sensor
50mm
Width sensor
18mm
Material of optical surface
Plastic
Length of sensor
50mm
Analogue output 4 mA ... 20 mA
Number of semiconductor outputs with signalling function
1
With communication interface RS-422
With communication interface analogue
With communication interface CANOpen
With communication interface SSD
Type of switching output
PNP/PNP
With communication interface DeviceNet
With reflector
With communication interface RS-232
Number of protected contact energized outputs
0
With communication interface INTERBUS
Explosion safety category for dust
None
Number of contact energized outputs with signalling function
0
Analogue output 0 mA ... 20 mA
With monitoring function downstream switching devices
Laser protection class
None
Type of light
Polarized red light
Switching frequency
250Hz
Suitable for safety functions
Degree of protection (IP)
IP65
With restart blockage
Max. output current at protected output
100mA
Min. reflector distance
1000mm
Type of safety according to IEC 61496-1
1
Construction type housing
Cuboid
Voltage type
AC/DC
Rated control supply voltage Us at DC
12 .. 24V
Ambient temperature
-25 .. 55°C
From same serie