Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Pre failure notice
No
With reflector
No
Analogue output 4 mA ... 20 mA
No
Analogue output 0 V ... 10 V
No
Max. switching distance
8000mm
Max. output current
100mA
Analogue output 0 mA ... 20 mA
No
With communication interface RS-485
No
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
Type of switching output
NPN/NPN
Type of electric connection
Connector M12
Explosion safety category for dust
None
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 0
Construction type housing
Cuboid
Sensing mode
Light-/dark switching
With communication interface SSI
No
Material housing
Plastic
Type of switch function
Breaker contact (NC)
Number of semiconductor outputs with signalling function
1
Setting procedure
Other
With communication interface AS-Interface
No
With communication interface analogue
No
With other analogue output
No
Width sensor
18mm
With communication interface INTERBUS
No
Number of protected semiconductor outputs
1
Analogue output -10 V ... +10 V
No
Ambient temperature
-25 - 55°C
Max. output current at protected output
100mA
Switching frequency
250Hz
Length of sensor
50mm
With communication interface RS-422
No
With communication interface CANOpen
No
Height of sensor
50mm
Material of optical surface
Plastic
With communication interface DeviceNet
No
With time function
No
With communication interface RS-232
No
Type of safety according to IEC 61496-1
1
With communication interface PROFIBUS
No
Response time
2ms
Rated switching distance
5000mm
With communication interface SSD
No
Type of light
Polarized red light
Laser protection class
None
With restart blockage
No
Suitable for safety functions
No
Min. reflector distance
1000mm
Voltage type
AC/DC
Degree of protection (IP)
IP65
Rated control supply voltage Us at DC
12 - 24V
With communication interface Ethernet
No
Explosion safety category for gas
None
With monitoring function downstream switching devices
No
From same serie
XUK9ANBNM12

Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Pre failure notice
With reflector
Analogue output 4 mA ... 20 mA
Analogue output 0 V ... 10 V
Max. switching distance
8000mm
Max. output current
100mA
Analogue output 0 mA ... 20 mA
With communication interface RS-485
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
Type of switching output
NPN/NPN
Type of electric connection
Connector M12
Explosion safety category for dust
None
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 0
Construction type housing
Cuboid
Sensing mode
Light-/dark switching
With communication interface SSI
Material housing
Plastic
Type of switch function
Breaker contact (NC)
Number of semiconductor outputs with signalling function
1
Setting procedure
Other
With communication interface AS-Interface
With communication interface analogue
With other analogue output
Width sensor
18mm
With communication interface INTERBUS
Number of protected semiconductor outputs
1
Analogue output -10 V ... +10 V
Ambient temperature
-25 .. 55°C
Max. output current at protected output
100mA
Switching frequency
250Hz
Length of sensor
50mm
With communication interface RS-422
With communication interface CANOpen
Height of sensor
50mm
Material of optical surface
Plastic
With communication interface DeviceNet
With time function
With communication interface RS-232
Type of safety according to IEC 61496-1
1
With communication interface PROFIBUS
Response time
2ms
Rated switching distance
5000mm
With communication interface SSD
Type of light
Polarized red light
Laser protection class
None
With restart blockage
Suitable for safety functions
Min. reflector distance
1000mm
Voltage type
AC/DC
Degree of protection (IP)
IP65
Rated control supply voltage Us at DC
12 .. 24V
With communication interface Ethernet
Explosion safety category for gas
None
With monitoring function downstream switching devices
From same serie