Details
- Sensors
- Light scanner with background masking
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
-mm
Transmission range of the safety field
-m
Switching voltage of OSSD at state "high"
-V
Wavelength of the sensor
-nm
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Operating distance
1000 - 1000mm
Analogue output 0 mA ... 20 mA
No
With other analogue output
No
Max. output current
100mA
Max. switching distance
1000mm
Triangulation
Background fade-out
Explosion safety category for gas
None
Number of protected contact energized outputs
0
With communication interface AS-Interface
No
With communication interface CANOpen
No
With communication interface RS-485
No
Rated switching distance
1000mm
With communication interface Ethernet
No
Adjustment range
1000 - 1000mm
Analogue output -10 V ... +10 V
No
With time function
No
Setting procedure
Manual adjustment
With communication interface DeviceNet
No
With communication interface RS-232
No
Number of protected semiconductor outputs
1
Analogue output 0 V ... 10 V
No
Pre failure notice
No
With communication interface INTERBUS
No
With communication interface PROFIBUS
No
With reflector
No
Analogue output 4 mA ... 20 mA
No
Number of semiconductor outputs with signalling function
1
With communication interface SSI
No
Type of interface for safety communication
Other
Type of switch function
Programmable/configurable
With communication interface RS-422
No
Explosion safety category for dust
None
With communication interface SSD
No
Operating distance
1000 - 1000mm
With communication interface analogue
No
Number of contact energized outputs with signalling function
0
Width sensor
18mm
Type of switching output
PNP/NPN
Material of optical surface
Plastic
Switching frequency
250Hz
Rated control supply voltage Us at AC 50HZ
24 - 240V
Response time
2ms
Rated control supply voltage Us at AC 60HZ
24 - 240V
Voltage type
AC/DC
With monitoring function downstream switching devices
No
Rated control supply voltage Us at DC
12 - 24V
Type of light
Laser diode, infrared light
Laser protection class
Class 1
Type of electric connection
Cable radial
Operation agent-safety class
Safety class 0
Material housing
Plastic
Max. output current at protected output
100mA
Construction type housing
Cuboid
Length of sensor
50mm
Ambient temperature
-25 - 55°C
Height of sensor
50mm
Type of safety according to IEC 61496-1
1
Sensing mode
Dark switching
Material of cable sheath
Polyvinyl chloride (PVC)
With restart blockage
No
Suitable for safety functions
No
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUK8AKSNL2
Details
- Sensors
- Light scanner with background masking
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
-mm
Transmission range of the safety field
-m
Switching voltage of OSSD at state "high"
-V
Wavelength of the sensor
-nm
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Operating distance
1000 .. 1000mm
Analogue output 0 mA ... 20 mA
With other analogue output
Max. output current
100mA
Max. switching distance
1000mm
Triangulation
Background fade-out
Explosion safety category for gas
None
Number of protected contact energized outputs
0
With communication interface AS-Interface
With communication interface CANOpen
With communication interface RS-485
Rated switching distance
1000mm
With communication interface Ethernet
Adjustment range
1000 .. 1000mm
Analogue output -10 V ... +10 V
With time function
Setting procedure
Manual adjustment
With communication interface DeviceNet
With communication interface RS-232
Number of protected semiconductor outputs
1
Analogue output 0 V ... 10 V
Pre failure notice
With communication interface INTERBUS
With communication interface PROFIBUS
With reflector
Analogue output 4 mA ... 20 mA
Number of semiconductor outputs with signalling function
1
With communication interface SSI
Type of interface for safety communication
Other
Type of switch function
Programmable/configurable
With communication interface RS-422
Explosion safety category for dust
None
With communication interface SSD
Operating distance
1000 .. 1000mm
With communication interface analogue
Number of contact energized outputs with signalling function
0
Width sensor
18mm
Type of switching output
PNP/NPN
Material of optical surface
Plastic
Switching frequency
250Hz
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Response time
2ms
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Voltage type
AC/DC
With monitoring function downstream switching devices
Rated control supply voltage Us at DC
12 .. 24V
Type of light
Laser diode, infrared light
Laser protection class
Class 1
Type of electric connection
Cable radial
Operation agent-safety class
Safety class 0
Material housing
Plastic
Max. output current at protected output
100mA
Construction type housing
Cuboid
Length of sensor
50mm
Ambient temperature
-25 .. 55°C
Height of sensor
50mm
Type of safety according to IEC 61496-1
1
Sensing mode
Dark switching
Material of cable sheath
Polyvinyl chloride (PVC)
With restart blockage
Suitable for safety functions
Degree of protection (IP)
IP30
From same serie