Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
With time function
No
With reflector
No
Scope of delivery of the one-way system
Receiver
Pre failure notice
No
With other analogue output
No
Setting procedure
Other
Analogue output 0 V ... 10 V
No
With communication interface CANOpen
No
With communication interface AS-Interface
No
With communication interface Ethernet
No
Max. opening angle
0°
With communication interface analogue
No
With communication interface PROFIBUS
No
Rated switching distance
30000mm
Max. output current
100mA
With communication interface RS-232
No
With communication interface RS-422
No
Max. switching distance
45000mm
With communication interface DeviceNet
No
Analogue output -10 V ... +10 V
No
Analogue output 4 mA ... 20 mA
No
With communication interface INTERBUS
No
Analogue output 0 mA ... 20 mA
No
Number of contact energized outputs with signalling function
0
Type of interface for safety communication
Other
Number of protected contact energized outputs
0
With communication interface SSD
No
Number of semiconductor outputs with signalling function
1
With communication interface SSI
No
Type of electric connection
Connector M12
Explosion safety category for dust
None
Type of switch function
Normally open contact (NO)
Operation agent-safety class
Safety class 0
Height of sensor
50mm
Material of optical surface
Plastic
Ambient temperature
-25 - 55°C
Voltage type
AC/DC
With communication interface RS-485
No
With monitoring function downstream switching devices
No
Material of cable sheath
Other
Type of light
Infrared light
Laser protection class
Other
With restart blockage
No
Degree of protection (IP)
IP65
Number of protected semiconductor outputs
0
Suitable for safety functions
No
Material housing
Plastic
Width sensor
50mm
Response time
2ms
Sensing mode
Dark switching
Explosion safety category for gas
None
Type of switching output
NPN/NPN
Construction type housing
Cuboid
Type of safety according to IEC 61496-1
1
Max. output current at protected output
100mA
Switching frequency
250Hz
Min. reflector distance
15000mm
Rated control supply voltage Us at DC
12 - 24V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUK2ANANM12R
Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
With time function
With reflector
Scope of delivery of the one-way system
Receiver
Pre failure notice
With other analogue output
Setting procedure
Other
Analogue output 0 V ... 10 V
With communication interface CANOpen
With communication interface AS-Interface
With communication interface Ethernet
Max. opening angle
0°
With communication interface analogue
With communication interface PROFIBUS
Rated switching distance
30000mm
Max. output current
100mA
With communication interface RS-232
With communication interface RS-422
Max. switching distance
45000mm
With communication interface DeviceNet
Analogue output -10 V ... +10 V
Analogue output 4 mA ... 20 mA
With communication interface INTERBUS
Analogue output 0 mA ... 20 mA
Number of contact energized outputs with signalling function
0
Type of interface for safety communication
Other
Number of protected contact energized outputs
0
With communication interface SSD
Number of semiconductor outputs with signalling function
1
With communication interface SSI
Type of electric connection
Connector M12
Explosion safety category for dust
None
Type of switch function
Normally open contact (NO)
Operation agent-safety class
Safety class 0
Height of sensor
50mm
Material of optical surface
Plastic
Ambient temperature
-25 .. 55°C
Voltage type
AC/DC
With communication interface RS-485
With monitoring function downstream switching devices
Material of cable sheath
Other
Type of light
Infrared light
Laser protection class
Other
With restart blockage
Degree of protection (IP)
IP65
Number of protected semiconductor outputs
0
Suitable for safety functions
Material housing
Plastic
Width sensor
50mm
Response time
2ms
Sensing mode
Dark switching
Explosion safety category for gas
None
Type of switching output
NPN/NPN
Construction type housing
Cuboid
Type of safety according to IEC 61496-1
1
Max. output current at protected output
100mA
Switching frequency
250Hz
Min. reflector distance
15000mm
Rated control supply voltage Us at DC
12 .. 24V