Aleta.hr

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

With communication interface DeviceNet

No

Number of protected contact energized outputs

0

Construction type housing

Cuboid

Max. output current

3000mA

With other analogue output

No

With communication interface AS-Interface

No

With communication interface RS-422

No

With communication interface PROFIBUS

No

With communication interface SSD

No

Analogue output -10 V ... +10 V

No

With communication interface INTERBUS

No

With communication interface Ethernet

No

Number of protected semiconductor outputs

0

Number of contact energized outputs with signalling function

1

With communication interface analogue

No

With communication interface RS-232

No

Type of electric connection

Cable radial

Setting procedure

Other

Type of interface for safety communication

Other

With communication interface CANOpen

No

Type of switch function

Change-over contact (NO/NC)

With communication interface RS-485

No

Number of semiconductor outputs with signalling function

0

Material housing

Plastic

Operation agent-safety class

Safety class 0

Height of sensor

50mm

Explosion safety category for dust

None

Width sensor

18mm

Type of switching output

Relay contact

Explosion safety category for gas

None

With communication interface SSI

No

Analogue output 0 V ... 10 V

No

With reflector

No

Rated control supply voltage Us at DC

24 - 240V

With monitoring function downstream switching devices

No

Laser protection class

None

Type of light

Infrared light

Suitable for safety functions

No

Degree of protection (IP)

IP65

With restart blockage

No

Voltage type

AC/DC

Analogue output 4 mA ... 20 mA

No

With time function

No

Analogue output 0 mA ... 20 mA

No

Switching frequency

20Hz

Pre failure notice

No

Min. reflector distance

5000mm

Rated control supply voltage Us at AC 60HZ

24 - 240V

Max. switching distance

10000mm

Rated switching distance

7000mm

Material of optical surface

Plastic

Response time

25ms

Ambient temperature

-25 - 55°C

Max. output current at protected output

100mA

Type of safety according to IEC 61496-1

1

Length of sensor

50mm

Sensing mode

Light switching

Rated control supply voltage Us at AC 50HZ

24 - 240V


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUK1ARCNL2

Main Product Image

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

With communication interface DeviceNet

Number of protected contact energized outputs

0

Construction type housing

Cuboid

Max. output current

3000mA

With other analogue output

With communication interface AS-Interface

With communication interface RS-422

With communication interface PROFIBUS

With communication interface SSD

Analogue output -10 V ... +10 V

With communication interface INTERBUS

With communication interface Ethernet

Number of protected semiconductor outputs

0

Number of contact energized outputs with signalling function

1

With communication interface analogue

With communication interface RS-232

Type of electric connection

Cable radial

Setting procedure

Other

Type of interface for safety communication

Other

With communication interface CANOpen

Type of switch function

Change-over contact (NO/NC)

With communication interface RS-485

Number of semiconductor outputs with signalling function

0

Material housing

Plastic

Operation agent-safety class

Safety class 0

Height of sensor

50mm

Explosion safety category for dust

None

Width sensor

18mm

Type of switching output

Relay contact

Explosion safety category for gas

None

With communication interface SSI

Analogue output 0 V ... 10 V

With reflector

Rated control supply voltage Us at DC

24 .. 240V

With monitoring function downstream switching devices

Laser protection class

None

Type of light

Infrared light

Suitable for safety functions

Degree of protection (IP)

IP65

With restart blockage

Voltage type

AC/DC

Analogue output 4 mA ... 20 mA

With time function

Analogue output 0 mA ... 20 mA

Switching frequency

20Hz

Pre failure notice

Min. reflector distance

5000mm

Rated control supply voltage Us at AC 60HZ

24 .. 240V

Max. switching distance

10000mm

Rated switching distance

7000mm

Material of optical surface

Plastic

Response time

25ms

Ambient temperature

-25 .. 55°C

Max. output current at protected output

100mA

Type of safety according to IEC 61496-1

1

Length of sensor

50mm

Sensing mode

Light switching

Rated control supply voltage Us at AC 50HZ

24 .. 240V

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.