Aleta.hr

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

With time function

No

Max. switching distance

10000mm

Max. output current

3000mA

Analogue output 0 V ... 10 V

No

Analogue output -10 V ... +10 V

No

Analogue output 0 mA ... 20 mA

No

Pre failure notice

No

Analogue output 4 mA ... 20 mA

No

With reflector

Yes

Rated switching distance

7000mm

Voltage type

AC/DC

Rated control supply voltage Us at DC

24 - 240V

With monitoring function downstream switching devices

No

With restart blockage

No

Type of light

Infrared light

Suitable for safety functions

No

With communication interface RS-422

No

Type of electric connection

Cable radial

Number of contact energized outputs with signalling function

0

Explosion safety category for gas

None

Explosion safety category for dust

None

Laser protection class

None

Width sensor

18mm

With communication interface analogue

No

Degree of protection (IP)

IP65

Setting procedure

Other

With communication interface DeviceNet

No

With communication interface PROFIBUS

No

With communication interface SSD

No

With communication interface CANOpen

No

With communication interface Ethernet

No

Number of semiconductor outputs with signalling function

1

With communication interface RS-232

No

Response time

25ms

Max. output current at protected output

100mA

Length of sensor

50mm

Material housing

Plastic

Ambient temperature

-25 - 55°C

With communication interface SSI

No

Number of protected contact energized outputs

0

Type of safety according to IEC 61496-1

1

With communication interface RS-485

No

Construction type housing

Cuboid

Min. reflector distance

5000mm

Number of protected semiconductor outputs

0

Type of interface for safety communication

Other

Operation agent-safety class

Safety class 0

Height of sensor

50mm

Type of switching output

Relay contact

Sensing mode

Light switching

With other analogue output

No

With communication interface INTERBUS

No

Material of optical surface

Plastic

Type of switch function

Change-over contact (NO/NC)

Rated control supply voltage Us at AC 50HZ

24 - 240V

With communication interface AS-Interface

No

Rated control supply voltage Us at AC 60HZ

24 - 240V

Switching frequency

20Hz


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUK1ARCNL10

Main Product Image

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

With time function

Max. switching distance

10000mm

Max. output current

3000mA

Analogue output 0 V ... 10 V

Analogue output -10 V ... +10 V

Analogue output 0 mA ... 20 mA

Pre failure notice

Analogue output 4 mA ... 20 mA

With reflector

Rated switching distance

7000mm

Voltage type

AC/DC

Rated control supply voltage Us at DC

24 .. 240V

With monitoring function downstream switching devices

With restart blockage

Type of light

Infrared light

Suitable for safety functions

With communication interface RS-422

Type of electric connection

Cable radial

Number of contact energized outputs with signalling function

0

Explosion safety category for gas

None

Explosion safety category for dust

None

Laser protection class

None

Width sensor

18mm

With communication interface analogue

Degree of protection (IP)

IP65

Setting procedure

Other

With communication interface DeviceNet

With communication interface PROFIBUS

With communication interface SSD

With communication interface CANOpen

With communication interface Ethernet

Number of semiconductor outputs with signalling function

1

With communication interface RS-232

Response time

25ms

Max. output current at protected output

100mA

Length of sensor

50mm

Material housing

Plastic

Ambient temperature

-25 .. 55°C

With communication interface SSI

Number of protected contact energized outputs

0

Type of safety according to IEC 61496-1

1

With communication interface RS-485

Construction type housing

Cuboid

Min. reflector distance

5000mm

Number of protected semiconductor outputs

0

Type of interface for safety communication

Other

Operation agent-safety class

Safety class 0

Height of sensor

50mm

Type of switching output

Relay contact

Sensing mode

Light switching

With other analogue output

With communication interface INTERBUS

Material of optical surface

Plastic

Type of switch function

Change-over contact (NO/NC)

Rated control supply voltage Us at AC 50HZ

24 .. 240V

With communication interface AS-Interface

Rated control supply voltage Us at AC 60HZ

24 .. 240V

Switching frequency

20Hz

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.