Aleta.hr

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

Max. switching distance

10000mm

Max. output current

100mA

Rated switching distance

7000mm

With time function

No

Analogue output 0 V ... 10 V

No

Analogue output 0 mA ... 20 mA

No

With other analogue output

No

Analogue output -10 V ... +10 V

No

With communication interface DeviceNet

No

Pre failure notice

No

With reflector

No

Laser protection class

None

With monitoring function downstream switching devices

No

Type of light

Infrared light

With restart blockage

No

Suitable for safety functions

No

Number of contact energized outputs with signalling function

0

Construction type housing

Cuboid

Ambient temperature

-25 - 55°C

Length of sensor

50mm

With communication interface AS-Interface

No

With communication interface CANOpen

No

With communication interface RS-485

No

With communication interface SSD

No

With communication interface INTERBUS

No

Degree of protection (IP)

IP65

With communication interface RS-422

No

Number of protected contact energized outputs

0

Explosion safety category for gas

None

Type of interface for safety communication

Other

Type of switch function

Normally open contact (NO)

With communication interface SSI

No

Explosion safety category for dust

None

Material of optical surface

Plastic

Sensing mode

Dark switching

Height of sensor

50mm

With communication interface RS-232

No

With communication interface analogue

No

Analogue output 4 mA ... 20 mA

No

Number of protected semiconductor outputs

0

Width sensor

18mm

Min. reflector distance

5000mm

Type of safety according to IEC 61496-1

1

Setting procedure

Other

Switching frequency

250Hz

Rated control supply voltage Us at DC

12 - 24V

With communication interface Ethernet

No

Max. output current at protected output

100mA

Material housing

Plastic

With communication interface PROFIBUS

No

Voltage type

AC/DC

Type of switching output

PNP/PNP

Type of electric connection

Connector M12

Operation agent-safety class

Safety class 0

Response time

2ms

Number of semiconductor outputs with signalling function

1


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUK1APANM12

Main Product Image

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

Max. switching distance

10000mm

Max. output current

100mA

Rated switching distance

7000mm

With time function

Analogue output 0 V ... 10 V

Analogue output 0 mA ... 20 mA

With other analogue output

Analogue output -10 V ... +10 V

With communication interface DeviceNet

Pre failure notice

With reflector

Laser protection class

None

With monitoring function downstream switching devices

Type of light

Infrared light

With restart blockage

Suitable for safety functions

Number of contact energized outputs with signalling function

0

Construction type housing

Cuboid

Ambient temperature

-25 .. 55°C

Length of sensor

50mm

With communication interface AS-Interface

With communication interface CANOpen

With communication interface RS-485

With communication interface SSD

With communication interface INTERBUS

Degree of protection (IP)

IP65

With communication interface RS-422

Number of protected contact energized outputs

0

Explosion safety category for gas

None

Type of interface for safety communication

Other

Type of switch function

Normally open contact (NO)

With communication interface SSI

Explosion safety category for dust

None

Material of optical surface

Plastic

Sensing mode

Dark switching

Height of sensor

50mm

With communication interface RS-232

With communication interface analogue

Analogue output 4 mA ... 20 mA

Number of protected semiconductor outputs

0

Width sensor

18mm

Min. reflector distance

5000mm

Type of safety according to IEC 61496-1

1

Setting procedure

Other

Switching frequency

250Hz

Rated control supply voltage Us at DC

12 .. 24V

With communication interface Ethernet

Max. output current at protected output

100mA

Material housing

Plastic

With communication interface PROFIBUS

Voltage type

AC/DC

Type of switching output

PNP/PNP

Type of electric connection

Connector M12

Operation agent-safety class

Safety class 0

Response time

2ms

Number of semiconductor outputs with signalling function

1