Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

Analogue output 0 V ... 10 V

No

Analogue output 4 mA ... 20 mA

No

With communication interface RS-422

No

With communication interface PROFIBUS

No

Number of protected semiconductor outputs

1

Type of switching output

PNP/PNP

Number of protected contact energized outputs

0

With communication interface RS-485

No

Type of interface for safety communication

Other

Explosion safety category for gas

None

Explosion safety category for dust

None

Material of optical surface

Plastic

Rated switching distance

7000mm

Max. switching distance

10000mm

With reflector

Yes

With communication interface analogue

No

Analogue output -10 V ... +10 V

No

Max. output current

100mA

Height of sensor

50mm

With time function

No

With communication interface INTERBUS

No

With communication interface DeviceNet

No

Analogue output 0 mA ... 20 mA

No

With communication interface AS-Interface

No

With communication interface RS-232

No

Setting procedure

Other

With other analogue output

No

Number of contact energized outputs with signalling function

0

With communication interface SSI

No

With communication interface Ethernet

No

Operation agent-safety class

Safety class 0

With communication interface CANOpen

No

Construction type housing

Cuboid

Type of switch function

Normally open contact (NO)

Number of semiconductor outputs with signalling function

1

Sensing mode

Dark switching

Length of sensor

50mm

Pre failure notice

No

Type of electric connection

Cable radial

Ambient temperature

-25 - 55°C

With monitoring function downstream switching devices

No

Laser protection class

None

Type of light

Infrared light

Suitable for safety functions

No

Degree of protection (IP)

IP65

With restart blockage

No

Width sensor

18mm

Max. output current at protected output

100mA

Min. reflector distance

5000mm

Voltage type

AC/DC

Type of safety according to IEC 61496-1

1

Rated control supply voltage Us at DC

12 - 24V

Response time

2ms

Material housing

Plastic

Switching frequency

250Hz

With communication interface SSD

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUK1APANL2

Main Product Image

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

Analogue output 0 V ... 10 V

Analogue output 4 mA ... 20 mA

With communication interface RS-422

With communication interface PROFIBUS

Number of protected semiconductor outputs

1

Type of switching output

PNP/PNP

Number of protected contact energized outputs

0

With communication interface RS-485

Type of interface for safety communication

Other

Explosion safety category for gas

None

Explosion safety category for dust

None

Material of optical surface

Plastic

Rated switching distance

7000mm

Max. switching distance

10000mm

With reflector

With communication interface analogue

Analogue output -10 V ... +10 V

Max. output current

100mA

Height of sensor

50mm

With time function

With communication interface INTERBUS

With communication interface DeviceNet

Analogue output 0 mA ... 20 mA

With communication interface AS-Interface

With communication interface RS-232

Setting procedure

Other

With other analogue output

Number of contact energized outputs with signalling function

0

With communication interface SSI

With communication interface Ethernet

Operation agent-safety class

Safety class 0

With communication interface CANOpen

Construction type housing

Cuboid

Type of switch function

Normally open contact (NO)

Number of semiconductor outputs with signalling function

1

Sensing mode

Dark switching

Length of sensor

50mm

Pre failure notice

Type of electric connection

Cable radial

Ambient temperature

-25 .. 55°C

With monitoring function downstream switching devices

Laser protection class

None

Type of light

Infrared light

Suitable for safety functions

Degree of protection (IP)

IP65

With restart blockage

Width sensor

18mm

Max. output current at protected output

100mA

Min. reflector distance

5000mm

Voltage type

AC/DC

Type of safety according to IEC 61496-1

1

Rated control supply voltage Us at DC

12 .. 24V

Response time

2ms

Material housing

Plastic

Switching frequency

250Hz

With communication interface SSD