Details
- Sensors
- Diffuse reflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Width sensor
-mm
Height of sensor
-mm
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
AWG-number
-
Operating distance
600 - 600mm
With time function
No
Pre failure notice
No
Operating distance
600 - 600mm
Analogue output 4 mA ... 20 mA
No
Analogue output 0 mA ... 20 mA
No
Analogue output 0 V ... 10 V
No
With reflector
No
Setting procedure
Manual adjustment
With communication interface AS-Interface
No
With communication interface DeviceNet
No
With communication interface PROFIBUS
No
With communication interface Ethernet
No
With communication interface INTERBUS
No
Analogue output -10 V ... +10 V
No
With communication interface RS-422
No
With communication interface analogue
No
Max. switching distance
800mm
With other analogue output
No
Max. output current
100mA
With communication interface CANOpen
No
Type of light
Infrared light
Material of cable sheath
Other
With restart blockage
No
Degree of protection (IP)
IP65
Suitable for safety functions
No
Ambient temperature
-25 - 55°C
Rated control supply voltage Us at DC
12 - 24V
Type of switch function
Normally open contact (NO)
Operation agent-safety class
Safety class 0
Diameter sensor
18mm
Max. output current at protected output
100mA
Type of switching output
NPN/NPN
Length of sensor
62mm
Number of protected contact energized outputs
0
Number of contact energized outputs with signalling function
0
With communication interface SSI
No
With communication interface RS-485
No
With communication interface SSD
No
Number of protected semiconductor outputs
1
Explosion safety category for gas
None
Type of electric connection
Cable radial
Type of interface for safety communication
Other
Explosion safety category for dust
None
Construction type housing
Cylinder, screw-thread
Sensing mode
Dark switching
Number of semiconductor outputs with signalling function
1
With communication interface RS-232
No
Min. reflector distance
0.3mm
Transmission range of the safety field
0.3m
Type of safety according to IEC 61496-1
1
Response time
1ms
With monitoring function downstream switching devices
No
Laser protection class
None
Voltage type
AC/DC
Material housing
Plastic
Material of optical surface
Plastic
Switching frequency
500Hz
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUB5ANANL2

Details
- Sensors
- Diffuse reflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Width sensor
-mm
Height of sensor
-mm
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
AWG-number
-
Operating distance
600 .. 600mm
With time function
Pre failure notice
Operating distance
600 .. 600mm
Analogue output 4 mA ... 20 mA
Analogue output 0 mA ... 20 mA
Analogue output 0 V ... 10 V
With reflector
Setting procedure
Manual adjustment
With communication interface AS-Interface
With communication interface DeviceNet
With communication interface PROFIBUS
With communication interface Ethernet
With communication interface INTERBUS
Analogue output -10 V ... +10 V
With communication interface RS-422
With communication interface analogue
Max. switching distance
800mm
With other analogue output
Max. output current
100mA
With communication interface CANOpen
Type of light
Infrared light
Material of cable sheath
Other
With restart blockage
Degree of protection (IP)
IP65
Suitable for safety functions
Ambient temperature
-25 .. 55°C
Rated control supply voltage Us at DC
12 .. 24V
Type of switch function
Normally open contact (NO)
Operation agent-safety class
Safety class 0
Diameter sensor
18mm
Max. output current at protected output
100mA
Type of switching output
NPN/NPN
Length of sensor
62mm
Number of protected contact energized outputs
0
Number of contact energized outputs with signalling function
0
With communication interface SSI
With communication interface RS-485
With communication interface SSD
Number of protected semiconductor outputs
1
Explosion safety category for gas
None
Type of electric connection
Cable radial
Type of interface for safety communication
Other
Explosion safety category for dust
None
Construction type housing
Cylinder, screw-thread
Sensing mode
Dark switching
Number of semiconductor outputs with signalling function
1
With communication interface RS-232
Min. reflector distance
0.3mm
Transmission range of the safety field
0.3m
Type of safety according to IEC 61496-1
1
Response time
1ms
With monitoring function downstream switching devices
Laser protection class
None
Voltage type
AC/DC
Material housing
Plastic
Material of optical surface
Plastic
Switching frequency
500Hz
From same serie