Details
- Sensors
- Diffuse reflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Width sensor
-mm
Height of sensor
-mm
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
AWG-number
-
Operating distance
100 - 100mm
Pre failure notice
No
With time function
No
Analogue output 4 mA ... 20 mA
No
Analogue output 0 mA ... 20 mA
No
With other analogue output
No
Setting procedure
Other
With communication interface CANOpen
No
With communication interface analogue
No
Max. switching distance
150mm
Max. output current
100mA
With reflector
No
With communication interface AS-Interface
No
Analogue output -10 V ... +10 V
No
Analogue output 0 V ... 10 V
No
With communication interface Ethernet
No
Material of cable sheath
Other
Suitable for safety functions
No
With restart blockage
No
Degree of protection (IP)
IP67K
Ambient temperature
-25 - 55°C
Rated control supply voltage Us at DC
12 - 24V
Type of interface for safety communication
Other
Explosion safety category for gas
None
Explosion safety category for dust
None
Diameter sensor
18mm
Material of optical surface
Plastic
Type of safety according to IEC 61496-1
1
Response time
1ms
Operation agent-safety class
Safety class 0
Switching frequency
500Hz
Max. output current at protected output
100mA
Material housing
Plastic
Type of light
Infrared light
With communication interface PROFIBUS
No
Transmission range of the safety field
3m
With communication interface SSD
No
With communication interface SSI
No
With communication interface DeviceNet
No
Type of electric connection
Connector M12
Type of switch function
Normally open contact (NO)
Number of protected semiconductor outputs
1
Number of contact energized outputs with signalling function
0
Construction type housing
Cylinder, screw-thread
With communication interface RS-422
No
Sensing mode
Light switching
Number of protected contact energized outputs
0
Type of switching output
NPN/NPN
With communication interface INTERBUS
No
Voltage type
AC/DC
Length of sensor
60mm
Min. reflector distance
0.3mm
With communication interface RS-232
No
Number of semiconductor outputs with signalling function
1
With communication interface RS-485
No
With monitoring function downstream switching devices
No
Laser protection class
None
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUB4ANANM12

Details
- Sensors
- Diffuse reflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Width sensor
-mm
Height of sensor
-mm
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
AWG-number
-
Operating distance
100 .. 100mm
Pre failure notice
With time function
Analogue output 4 mA ... 20 mA
Analogue output 0 mA ... 20 mA
With other analogue output
Setting procedure
Other
With communication interface CANOpen
With communication interface analogue
Max. switching distance
150mm
Max. output current
100mA
With reflector
With communication interface AS-Interface
Analogue output -10 V ... +10 V
Analogue output 0 V ... 10 V
With communication interface Ethernet
Material of cable sheath
Other
Suitable for safety functions
With restart blockage
Degree of protection (IP)
IP67K
Ambient temperature
-25 .. 55°C
Rated control supply voltage Us at DC
12 .. 24V
Type of interface for safety communication
Other
Explosion safety category for gas
None
Explosion safety category for dust
None
Diameter sensor
18mm
Material of optical surface
Plastic
Type of safety according to IEC 61496-1
1
Response time
1ms
Operation agent-safety class
Safety class 0
Switching frequency
500Hz
Max. output current at protected output
100mA
Material housing
Plastic
Type of light
Infrared light
With communication interface PROFIBUS
Transmission range of the safety field
3m
With communication interface SSD
With communication interface SSI
With communication interface DeviceNet
Type of electric connection
Connector M12
Type of switch function
Normally open contact (NO)
Number of protected semiconductor outputs
1
Number of contact energized outputs with signalling function
0
Construction type housing
Cylinder, screw-thread
With communication interface RS-422
Sensing mode
Light switching
Number of protected contact energized outputs
0
Type of switching output
NPN/NPN
With communication interface INTERBUS
Voltage type
AC/DC
Length of sensor
60mm
Min. reflector distance
0.3mm
With communication interface RS-232
Number of semiconductor outputs with signalling function
1
With communication interface RS-485
With monitoring function downstream switching devices
Laser protection class
None
From same serie
We use cookies to enhance your experience.