Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
AWG-number
-
With reflector
No
Analogue output 0 mA ... 20 mA
No
Analogue output -10 V ... +10 V
No
With communication interface AS-Interface
No
With communication interface Ethernet
No
With communication interface analogue
No
Number of contact energized outputs with signalling function
0
With communication interface INTERBUS
No
With communication interface SSI
No
Max. opening angle
0°
With communication interface PROFIBUS
No
With other analogue output
No
Max. switching distance
20mm
With communication interface RS-232
No
With time function
No
With communication interface RS-485
No
With communication interface DeviceNet
No
Setting procedure
Teach-In
With communication interface CANOpen
No
Pre failure notice
No
Analogue output 4 mA ... 20 mA
No
Rated switching distance
15mm
Scope of delivery of the one-way system
Receiver
Voltage type
AC/DC
With monitoring function downstream switching devices
No
Type of light
Infrared light
Laser protection class
Other
With restart blockage
No
Material of cable sheath
Other
Suitable for safety functions
No
Degree of protection (IP)
IP65
With communication interface SSD
No
Max. output current
100mA
Analogue output 0 V ... 10 V
No
Type of switching output
PNP/PNP
Type of interface for safety communication
Other
Type of switch function
Breaker contact (NC)
With communication interface RS-422
No
Explosion safety category for dust
None
Type of electric connection
Cable radial
Length of sensor
60mm
Number of protected semiconductor outputs
0
Material of optical surface
Plastic
Response time
1ms
Diameter sensor
18mm
Material housing
Metal
Max. output current at protected output
100mA
Min. reflector distance
5000mm
Rated control supply voltage Us at DC
12 - 24V
Sensing mode
Dark switching
Number of protected contact energized outputs
0
Number of semiconductor outputs with signalling function
1
Ambient temperature
-25 - 55°C
Operation agent-safety class
Safety class 0
Construction type housing
Cylinder, screw-thread
Switching frequency
500Hz
Explosion safety category for gas
None
Type of safety according to IEC 61496-1
1
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUB2BPBNL2R
Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
AWG-number
-
With reflector
Analogue output 0 mA ... 20 mA
Analogue output -10 V ... +10 V
With communication interface AS-Interface
With communication interface Ethernet
With communication interface analogue
Number of contact energized outputs with signalling function
0
With communication interface INTERBUS
With communication interface SSI
Max. opening angle
0°
With communication interface PROFIBUS
With other analogue output
Max. switching distance
20mm
With communication interface RS-232
With time function
With communication interface RS-485
With communication interface DeviceNet
Setting procedure
Teach-In
With communication interface CANOpen
Pre failure notice
Analogue output 4 mA ... 20 mA
Rated switching distance
15mm
Scope of delivery of the one-way system
Receiver
Voltage type
AC/DC
With monitoring function downstream switching devices
Type of light
Infrared light
Laser protection class
Other
With restart blockage
Material of cable sheath
Other
Suitable for safety functions
Degree of protection (IP)
IP65
With communication interface SSD
Max. output current
100mA
Analogue output 0 V ... 10 V
Type of switching output
PNP/PNP
Type of interface for safety communication
Other
Type of switch function
Breaker contact (NC)
With communication interface RS-422
Explosion safety category for dust
None
Type of electric connection
Cable radial
Length of sensor
60mm
Number of protected semiconductor outputs
0
Material of optical surface
Plastic
Response time
1ms
Diameter sensor
18mm
Material housing
Metal
Max. output current at protected output
100mA
Min. reflector distance
5000mm
Rated control supply voltage Us at DC
12 .. 24V
Sensing mode
Dark switching
Number of protected contact energized outputs
0
Number of semiconductor outputs with signalling function
1
Ambient temperature
-25 .. 55°C
Operation agent-safety class
Safety class 0
Construction type housing
Cylinder, screw-thread
Switching frequency
500Hz
Explosion safety category for gas
None
Type of safety according to IEC 61496-1
1
From same serie