Aleta.hr

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated switching distance

15000mm

Pre failure notice

No

Max. opening angle

90°

With time function

No

Analogue output 0 V ... 10 V

No

With reflector

No

Max. output current

100mA

Analogue output 4 mA ... 20 mA

No

Analogue output -10 V ... +10 V

No

Scope of delivery of the one-way system

Receiver

With communication interface AS-Interface

No

With other analogue output

No

Analogue output 0 mA ... 20 mA

No

Setting procedure

Other

With communication interface RS-232

No

With communication interface CANOpen

No

With communication interface analogue

No

With communication interface DeviceNet

No

With communication interface Ethernet

No

With communication interface SSD

No

With communication interface RS-485

No

Number of semiconductor outputs with signalling function

0

Number of contact energized outputs with signalling function

0

With communication interface SSI

No

With communication interface PROFIBUS

No

With communication interface RS-422

No

With communication interface INTERBUS

No

Max. switching distance

20000mm

Number of protected semiconductor outputs

0

Type of switch function

Normally open contact (NO)

Explosion safety category for gas

None

Max. output current at protected output

35mA

Diameter sensor

18mm

Type of switching output

NPN/NPN

Type of electric connection

Cable radial

Explosion safety category for dust

None

Number of protected contact energized outputs

0

Switching frequency

500Hz

Sensing mode

Light switching

Response time

0ms

Voltage type

AC/DC

Type of light

Laser diode, infrared light

Material of cable sheath

Other

With restart blockage

No

Operation agent-safety class

Safety class 0

Suitable for safety functions

No

Degree of protection (IP)

IP65

Material housing

Metal

Material of optical surface

Other

Type of interface for safety communication

Other

Construction type housing

Cylinder, screw-thread

Type of safety according to IEC 61496-1

1

With monitoring function downstream switching devices

No

Laser protection class

None

Ambient temperature

-25 - 55°C


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUB2BNAWM12R

Main Product Image

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated switching distance

15000mm

Pre failure notice

Max. opening angle

90°

With time function

Analogue output 0 V ... 10 V

With reflector

Max. output current

100mA

Analogue output 4 mA ... 20 mA

Analogue output -10 V ... +10 V

Scope of delivery of the one-way system

Receiver

With communication interface AS-Interface

With other analogue output

Analogue output 0 mA ... 20 mA

Setting procedure

Other

With communication interface RS-232

With communication interface CANOpen

With communication interface analogue

With communication interface DeviceNet

With communication interface Ethernet

With communication interface SSD

With communication interface RS-485

Number of semiconductor outputs with signalling function

0

Number of contact energized outputs with signalling function

0

With communication interface SSI

With communication interface PROFIBUS

With communication interface RS-422

With communication interface INTERBUS

Max. switching distance

20000mm

Number of protected semiconductor outputs

0

Type of switch function

Normally open contact (NO)

Explosion safety category for gas

None

Max. output current at protected output

35mA

Diameter sensor

18mm

Type of switching output

NPN/NPN

Type of electric connection

Cable radial

Explosion safety category for dust

None

Number of protected contact energized outputs

0

Switching frequency

500Hz

Sensing mode

Light switching

Response time

0ms

Voltage type

AC/DC

Type of light

Laser diode, infrared light

Material of cable sheath

Other

With restart blockage

Operation agent-safety class

Safety class 0

Suitable for safety functions

Degree of protection (IP)

IP65

Material housing

Metal

Material of optical surface

Other

Type of interface for safety communication

Other

Construction type housing

Cylinder, screw-thread

Type of safety according to IEC 61496-1

1

With monitoring function downstream switching devices

Laser protection class

None

Ambient temperature

-25 .. 55°C

From same serie