Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated switching distance
15000mm
Pre failure notice
No
Analogue output 0 mA ... 20 mA
No
With time function
No
With communication interface RS-485
No
With communication interface analogue
No
With communication interface INTERBUS
No
Number of protected semiconductor outputs
1
With communication interface Ethernet
No
With communication interface RS-422
No
Max. output current at protected output
100mA
With reflector
No
Max. opening angle
0°
Analogue output 0 V ... 10 V
No
Analogue output 4 mA ... 20 mA
No
Scope of delivery of the one-way system
Receiver
Setting procedure
Other
Max. output current
100mA
With communication interface SSD
No
Number of protected contact energized outputs
0
With communication interface SSI
No
Explosion safety category for dust
None
Number of contact energized outputs with signalling function
0
With communication interface PROFIBUS
No
With other analogue output
No
Type of switching output
NPN/NPN
Analogue output -10 V ... +10 V
No
With communication interface RS-232
No
Material housing
Plastic
With communication interface DeviceNet
No
Material of optical surface
Other
Type of electric connection
Cable radial
Explosion safety category for gas
None
With communication interface AS-Interface
No
Type of switch function
Breaker contact (NC)
Type of interface for safety communication
Other
With communication interface CANOpen
No
Number of semiconductor outputs with signalling function
1
Operation agent-safety class
Safety class 0
Max. switching distance
20000mm
With monitoring function downstream switching devices
No
Laser protection class
None
Type of light
Infrared light
Suitable for safety functions
No
With restart blockage
No
Degree of protection (IP)
IP65
Material of cable sheath
Other
Ambient temperature
-25 - 55°C
Response time
1ms
Rated control supply voltage Us at DC
12 - 24V
Construction type housing
Cylinder, screw-thread
Type of safety according to IEC 61496-1
1
Length of sensor
46mm
Diameter sensor
18mm
Sensing mode
Light switching
Switching frequency
500Hz
Voltage type
AC/DC
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUB2ANBNL2R

Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated switching distance
15000mm
Pre failure notice
Analogue output 0 mA ... 20 mA
With time function
With communication interface RS-485
With communication interface analogue
With communication interface INTERBUS
Number of protected semiconductor outputs
1
With communication interface Ethernet
With communication interface RS-422
Max. output current at protected output
100mA
With reflector
Max. opening angle
0°
Analogue output 0 V ... 10 V
Analogue output 4 mA ... 20 mA
Scope of delivery of the one-way system
Receiver
Setting procedure
Other
Max. output current
100mA
With communication interface SSD
Number of protected contact energized outputs
0
With communication interface SSI
Explosion safety category for dust
None
Number of contact energized outputs with signalling function
0
With communication interface PROFIBUS
With other analogue output
Type of switching output
NPN/NPN
Analogue output -10 V ... +10 V
With communication interface RS-232
Material housing
Plastic
With communication interface DeviceNet
Material of optical surface
Other
Type of electric connection
Cable radial
Explosion safety category for gas
None
With communication interface AS-Interface
Type of switch function
Breaker contact (NC)
Type of interface for safety communication
Other
With communication interface CANOpen
Number of semiconductor outputs with signalling function
1
Operation agent-safety class
Safety class 0
Max. switching distance
20000mm
With monitoring function downstream switching devices
Laser protection class
None
Type of light
Infrared light
Suitable for safety functions
With restart blockage
Degree of protection (IP)
IP65
Material of cable sheath
Other
Ambient temperature
-25 .. 55°C
Response time
1ms
Rated control supply voltage Us at DC
12 .. 24V
Construction type housing
Cylinder, screw-thread
Type of safety according to IEC 61496-1
1
Length of sensor
46mm
Diameter sensor
18mm
Sensing mode
Light switching
Switching frequency
500Hz
Voltage type
AC/DC
From same serie
We use cookies to enhance your experience.