Degree of protection (IP)

IP65

Voltage type

DC

Material housing

Plastic

Rated control supply voltage Us at DC

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Rated control supply voltage Us at AC 50HZ

- - -V

Type of electric connection

Connector M12

Explosion safety category for dust

None

Length of sensor

-mm

Width sensor

-mm

Diameter sensor

18mm

Construction type housing

Cylinder, screw-thread

Type of interface for safety communication

Other

With monitoring function downstream switching devices

No

Switching frequency

500Hz

Number of protected semiconductor outputs

0

Type of switching output

NPN

Type of switch function

Normally open contact (NO)

Number of semiconductor outputs with signalling function

0

Explosion safety category for gas

None

Height of sensor

-mm

Suitable for safety functions

No

Number of protected contact energized outputs

0

Number of contact energized outputs with signalling function

0

Max. output current at protected output

35mA

Ambient temperature

-25 - 55°C

Max. output current

100mA

With restart blockage

No

Response time

-ms

With communication interface RS-232

No

Transmission range of the safety field

-m

Type of safety according to IEC 61496-1

1

Material of cable sheath

Other

Wavelength of the sensor

-nm

Operation agent-safety class

Safety class 0

Switching voltage of OSSD at state "high"

-V

With communication interface Ethernet

No

With communication interface RS-485

No

Setting procedure

Other

With time function

No

Analogue output 0 V ... 10 V

No

Analogue output 0 mA ... 20 mA

No

Analogue output 4 mA ... 20 mA

No

Analogue output -10 V ... +10 V

No

Type of light

Laser diode, infrared light

Laser protection class

None

Material of optical surface

Other

With other analogue output

No

Pre failure notice

No

With communication interface CANOpen

No

With communication interface AS-Interface

No

With communication interface analogue

No

With communication interface INTERBUS

No

With communication interface DeviceNet

No

With communication interface SSD

No

With communication interface RS-422

No

With communication interface PROFIBUS

No

With communication interface SSI

No

Max. switching distance

20000mm

With reflector

No

Sensing mode

Light switching

Min. reflector distance

-mm

Light dot

-mm²

Rated switching distance

15000mm

AWG-number

-

Scope of delivery of the one-way system

Receiver

Max. opening angle

90°


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUB2ANAWM12R

Main Product Image

Details

  • Sensors
  • One-way light barrier
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP65

Voltage type

DC

Material housing

Plastic

Rated control supply voltage Us at DC

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated control supply voltage Us at AC 50HZ

- .. -V

Type of electric connection

Connector M12

Explosion safety category for dust

None

Length of sensor

-mm

Width sensor

-mm

Diameter sensor

18mm

Construction type housing

Cylinder, screw-thread

Type of interface for safety communication

Other

With monitoring function downstream switching devices

Switching frequency

500Hz

Number of protected semiconductor outputs

0

Type of switching output

NPN

Type of switch function

Normally open contact (NO)

Number of semiconductor outputs with signalling function

0

Explosion safety category for gas

None

Height of sensor

-mm

Suitable for safety functions

Number of protected contact energized outputs

0

Number of contact energized outputs with signalling function

0

Max. output current at protected output

35mA

Ambient temperature

-25 .. 55°C

Max. output current

100mA

With restart blockage

Response time

-ms

With communication interface RS-232

Transmission range of the safety field

-m

Type of safety according to IEC 61496-1

1

Material of cable sheath

Other

Wavelength of the sensor

-nm

Operation agent-safety class

Safety class 0

Switching voltage of OSSD at state "high"

-V

With communication interface Ethernet

With communication interface RS-485

Setting procedure

Other

With time function

Analogue output 0 V ... 10 V

Analogue output 0 mA ... 20 mA

Analogue output 4 mA ... 20 mA

Analogue output -10 V ... +10 V

Type of light

Laser diode, infrared light

Laser protection class

None

Material of optical surface

Other

With other analogue output

Pre failure notice

With communication interface CANOpen

With communication interface AS-Interface

With communication interface analogue

With communication interface INTERBUS

With communication interface DeviceNet

With communication interface SSD

With communication interface RS-422

With communication interface PROFIBUS

With communication interface SSI

Max. switching distance

20000mm

With reflector

Sensing mode

Light switching

Min. reflector distance

-mm

Light dot

-mm²

Rated switching distance

15000mm

AWG-number

-

Scope of delivery of the one-way system

Receiver

Max. opening angle

90°

From same serie