Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
Pre failure notice
No
With time function
No
Rated switching distance
4000mm
Analogue output 0 mA ... 20 mA
No
Analogue output 0 V ... 10 V
No
With reflector
Yes
Analogue output -10 V ... +10 V
No
Analogue output 4 mA ... 20 mA
No
Setting procedure
Other
With communication interface DeviceNet
No
With communication interface CANOpen
No
With communication interface analogue
No
With communication interface AS-Interface
No
With communication interface Ethernet
No
With communication interface INTERBUS
No
With communication interface PROFIBUS
No
With communication interface RS-232
No
With communication interface RS-485
No
With communication interface SSI
No
Number of contact energized outputs with signalling function
0
Number of semiconductor outputs with signalling function
1
Type of interface for safety communication
Other
With communication interface SSD
No
Number of protected semiconductor outputs
1
Type of electric connection
Cable radial
Type of switch function
Normally open contact (NO)
Max. switching distance
5500mm
With communication interface RS-422
No
With other analogue output
No
Max. output current
100mA
Type of switching output
PNP/PNP
Operation agent-safety class
Safety class 0
Diameter sensor
18mm
Laser protection class
None
Type of light
Infrared light
With restart blockage
No
Suitable for safety functions
No
Degree of protection (IP)
IP65
Length of sensor
46mm
Material housing
Metal
Material of optical surface
Plastic
Ambient temperature
-25 - 55°C
Switching frequency
500Hz
Rated control supply voltage Us at DC
12 - 24V
Construction type housing
Cylinder, screw-thread
Explosion safety category for gas
None
Response time
1ms
Explosion safety category for dust
None
Max. output current at protected output
100mA
Number of protected contact energized outputs
0
Voltage type
AC/DC
With monitoring function downstream switching devices
No
Min. reflector distance
1000mm
Sensing mode
Dark switching
Type of safety according to IEC 61496-1
1
From same serie
XUB1BPANL2

Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
Pre failure notice
With time function
Rated switching distance
4000mm
Analogue output 0 mA ... 20 mA
Analogue output 0 V ... 10 V
With reflector
Analogue output -10 V ... +10 V
Analogue output 4 mA ... 20 mA
Setting procedure
Other
With communication interface DeviceNet
With communication interface CANOpen
With communication interface analogue
With communication interface AS-Interface
With communication interface Ethernet
With communication interface INTERBUS
With communication interface PROFIBUS
With communication interface RS-232
With communication interface RS-485
With communication interface SSI
Number of contact energized outputs with signalling function
0
Number of semiconductor outputs with signalling function
1
Type of interface for safety communication
Other
With communication interface SSD
Number of protected semiconductor outputs
1
Type of electric connection
Cable radial
Type of switch function
Normally open contact (NO)
Max. switching distance
5500mm
With communication interface RS-422
With other analogue output
Max. output current
100mA
Type of switching output
PNP/PNP
Operation agent-safety class
Safety class 0
Diameter sensor
18mm
Laser protection class
None
Type of light
Infrared light
With restart blockage
Suitable for safety functions
Degree of protection (IP)
IP65
Length of sensor
46mm
Material housing
Metal
Material of optical surface
Plastic
Ambient temperature
-25 .. 55°C
Switching frequency
500Hz
Rated control supply voltage Us at DC
12 .. 24V
Construction type housing
Cylinder, screw-thread
Explosion safety category for gas
None
Response time
1ms
Explosion safety category for dust
None
Max. output current at protected output
100mA
Number of protected contact energized outputs
0
Voltage type
AC/DC
With monitoring function downstream switching devices
Min. reflector distance
1000mm
Sensing mode
Dark switching
Type of safety according to IEC 61496-1
1
From same serie