Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
Max. output current
100mA
With communication interface AS-Interface
No
With communication interface Ethernet
No
Analogue output -10 V ... +10 V
No
Analogue output 0 V ... 10 V
No
Rated switching distance
4000mm
Max. switching distance
5500mm
Analogue output 0 mA ... 20 mA
No
With communication interface CANOpen
No
Analogue output 4 mA ... 20 mA
No
With communication interface DeviceNet
No
Pre failure notice
No
With time function
No
With other analogue output
No
With communication interface analogue
No
With reflector
No
Setting procedure
Other
Laser protection class
None
Type of light
Infrared light
With restart blockage
No
Suitable for safety functions
No
Degree of protection (IP)
IP67K
Construction type housing
Cylinder, screw-thread
Material of optical surface
Plastic
Ambient temperature
-25 - 55°C
With communication interface SSD
No
Type of switch function
Normally open contact (NO)
Explosion safety category for gas
None
Max. output current at protected output
100mA
Sensing mode
Light-/dark switching
Min. reflector distance
1000mm
Length of sensor
76mm
Explosion safety category for dust
None
Response time
1ms
Number of protected semiconductor outputs
1
Type of safety according to IEC 61496-1
1
Diameter sensor
18mm
Material housing
Metal
With communication interface INTERBUS
No
With communication interface SSI
No
With communication interface RS-422
No
Number of protected contact energized outputs
0
Number of contact energized outputs with signalling function
0
With communication interface PROFIBUS
No
Type of electric connection
Connector M12
With communication interface RS-232
No
Number of semiconductor outputs with signalling function
1
Type of switching output
NPN/NPN
Operation agent-safety class
Safety class 0
With communication interface RS-485
No
Type of interface for safety communication
Other
Switching frequency
500Hz
Rated control supply voltage Us at DC
12 - 24V
With monitoring function downstream switching devices
No
Voltage type
AC/DC
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUB1BNAWM12

Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
Max. output current
100mA
With communication interface AS-Interface
With communication interface Ethernet
Analogue output -10 V ... +10 V
Analogue output 0 V ... 10 V
Rated switching distance
4000mm
Max. switching distance
5500mm
Analogue output 0 mA ... 20 mA
With communication interface CANOpen
Analogue output 4 mA ... 20 mA
With communication interface DeviceNet
Pre failure notice
With time function
With other analogue output
With communication interface analogue
With reflector
Setting procedure
Other
Laser protection class
None
Type of light
Infrared light
With restart blockage
Suitable for safety functions
Degree of protection (IP)
IP67K
Construction type housing
Cylinder, screw-thread
Material of optical surface
Plastic
Ambient temperature
-25 .. 55°C
With communication interface SSD
Type of switch function
Normally open contact (NO)
Explosion safety category for gas
None
Max. output current at protected output
100mA
Sensing mode
Light-/dark switching
Min. reflector distance
1000mm
Length of sensor
76mm
Explosion safety category for dust
None
Response time
1ms
Number of protected semiconductor outputs
1
Type of safety according to IEC 61496-1
1
Diameter sensor
18mm
Material housing
Metal
With communication interface INTERBUS
With communication interface SSI
With communication interface RS-422
Number of protected contact energized outputs
0
Number of contact energized outputs with signalling function
0
With communication interface PROFIBUS
Type of electric connection
Connector M12
With communication interface RS-232
Number of semiconductor outputs with signalling function
1
Type of switching output
NPN/NPN
Operation agent-safety class
Safety class 0
With communication interface RS-485
Type of interface for safety communication
Other
Switching frequency
500Hz
Rated control supply voltage Us at DC
12 .. 24V
With monitoring function downstream switching devices
Voltage type
AC/DC
From same serie
We use cookies to enhance your experience.