Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Pre failure notice
No
Rated switching distance
4000mm
With time function
No
Analogue output 0 mA ... 20 mA
No
With reflector
Yes
With other analogue output
No
Analogue output 0 V ... 10 V
No
Analogue output -10 V ... +10 V
No
With communication interface analogue
No
With communication interface CANOpen
No
With communication interface PROFIBUS
No
With communication interface AS-Interface
No
With communication interface SSD
No
With communication interface RS-422
No
With communication interface Ethernet
No
Number of contact energized outputs with signalling function
0
Type of interface for safety communication
Other
Number of protected semiconductor outputs
1
Type of electric connection
Connector M12
With communication interface RS-485
No
With communication interface SSI
No
Setting procedure
Other
With communication interface DeviceNet
No
Max. output current
100mA
Analogue output 4 mA ... 20 mA
No
Number of semiconductor outputs with signalling function
1
Max. switching distance
5500mm
With communication interface RS-232
No
Number of protected contact energized outputs
0
Type of switch function
Normally open contact (NO)
Explosion safety category for dust
None
Length of sensor
76mm
Sensing mode
Dark switching
Material housing
Metal
Diameter sensor
18mm
Ambient temperature
-25 - 55°C
Laser protection class
None
Type of light
Infrared light
Suitable for safety functions
No
With restart blockage
No
Degree of protection (IP)
IP67K
Explosion safety category for gas
None
Operation agent-safety class
Safety class 0
Type of switching output
NPN/NPN
Construction type housing
Cylinder, screw-thread
Material of optical surface
Plastic
Switching frequency
500Hz
Response time
1ms
With monitoring function downstream switching devices
No
Voltage type
AC/DC
With communication interface INTERBUS
No
Type of safety according to IEC 61496-1
1
Rated control supply voltage Us at DC
12 - 24V
Max. output current at protected output
100mA
Min. reflector distance
1000mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUB1BNANM12

Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Pre failure notice
Rated switching distance
4000mm
With time function
Analogue output 0 mA ... 20 mA
With reflector
With other analogue output
Analogue output 0 V ... 10 V
Analogue output -10 V ... +10 V
With communication interface analogue
With communication interface CANOpen
With communication interface PROFIBUS
With communication interface AS-Interface
With communication interface SSD
With communication interface RS-422
With communication interface Ethernet
Number of contact energized outputs with signalling function
0
Type of interface for safety communication
Other
Number of protected semiconductor outputs
1
Type of electric connection
Connector M12
With communication interface RS-485
With communication interface SSI
Setting procedure
Other
With communication interface DeviceNet
Max. output current
100mA
Analogue output 4 mA ... 20 mA
Number of semiconductor outputs with signalling function
1
Max. switching distance
5500mm
With communication interface RS-232
Number of protected contact energized outputs
0
Type of switch function
Normally open contact (NO)
Explosion safety category for dust
None
Length of sensor
76mm
Sensing mode
Dark switching
Material housing
Metal
Diameter sensor
18mm
Ambient temperature
-25 .. 55°C
Laser protection class
None
Type of light
Infrared light
Suitable for safety functions
With restart blockage
Degree of protection (IP)
IP67K
Explosion safety category for gas
None
Operation agent-safety class
Safety class 0
Type of switching output
NPN/NPN
Construction type housing
Cylinder, screw-thread
Material of optical surface
Plastic
Switching frequency
500Hz
Response time
1ms
With monitoring function downstream switching devices
Voltage type
AC/DC
With communication interface INTERBUS
Type of safety according to IEC 61496-1
1
Rated control supply voltage Us at DC
12 .. 24V
Max. output current at protected output
100mA
Min. reflector distance
1000mm
From same serie