Aleta.hr

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Width sensor

-mm

Height of sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

With time function

No

Rated switching distance

4000mm

Pre failure notice

No

With communication interface RS-232

No

With communication interface DeviceNet

No

With communication interface AS-Interface

No

With communication interface PROFIBUS

No

Analogue output 0 mA ... 20 mA

No

With communication interface CANOpen

No

Analogue output -10 V ... +10 V

No

With reflector

No

Setting procedure

Other

Analogue output 0 V ... 10 V

No

Max. switching distance

5500mm

Analogue output 4 mA ... 20 mA

No

With communication interface analogue

No

With other analogue output

No

With communication interface INTERBUS

No

Max. output current

100mA

Explosion safety category for gas

None

Laser protection class

None

Explosion safety category for dust

None

With communication interface RS-422

No

Number of contact energized outputs with signalling function

0

Number of protected semiconductor outputs

1

With communication interface SSI

No

Number of semiconductor outputs with signalling function

1

With communication interface RS-485

No

Type of switch function

Breaker contact (NC)

Type of interface for safety communication

Other

Type of electric connection

Cable radial

Operation agent-safety class

Safety class 0

Length of sensor

62mm

With communication interface SSD

No

Number of protected contact energized outputs

0

Material housing

Plastic

Construction type housing

Cylinder, screw-thread

Type of switching output

PNP/PNP

Type of light

Infrared light

With restart blockage

No

Degree of protection (IP)

IP67K

Suitable for safety functions

No

Max. output current at protected output

100mA

Response time

1ms

Ambient temperature

-25 - 55°C

Diameter sensor

18mm

Switching frequency

500Hz

Rated control supply voltage Us at DC

12 - 24V

Sensing mode

Light-/dark switching

Type of safety according to IEC 61496-1

1

With monitoring function downstream switching devices

No

Material of optical surface

Plastic

Voltage type

AC/DC

Min. reflector distance

1000mm

With communication interface Ethernet

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUB1APBWL2

Main Product Image

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Width sensor

-mm

Height of sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

With time function

Rated switching distance

4000mm

Pre failure notice

With communication interface RS-232

With communication interface DeviceNet

With communication interface AS-Interface

With communication interface PROFIBUS

Analogue output 0 mA ... 20 mA

With communication interface CANOpen

Analogue output -10 V ... +10 V

With reflector

Setting procedure

Other

Analogue output 0 V ... 10 V

Max. switching distance

5500mm

Analogue output 4 mA ... 20 mA

With communication interface analogue

With other analogue output

With communication interface INTERBUS

Max. output current

100mA

Explosion safety category for gas

None

Laser protection class

None

Explosion safety category for dust

None

With communication interface RS-422

Number of contact energized outputs with signalling function

0

Number of protected semiconductor outputs

1

With communication interface SSI

Number of semiconductor outputs with signalling function

1

With communication interface RS-485

Type of switch function

Breaker contact (NC)

Type of interface for safety communication

Other

Type of electric connection

Cable radial

Operation agent-safety class

Safety class 0

Length of sensor

62mm

With communication interface SSD

Number of protected contact energized outputs

0

Material housing

Plastic

Construction type housing

Cylinder, screw-thread

Type of switching output

PNP/PNP

Type of light

Infrared light

With restart blockage

Degree of protection (IP)

IP67K

Suitable for safety functions

Max. output current at protected output

100mA

Response time

1ms

Ambient temperature

-25 .. 55°C

Diameter sensor

18mm

Switching frequency

500Hz

Rated control supply voltage Us at DC

12 .. 24V

Sensing mode

Light-/dark switching

Type of safety according to IEC 61496-1

1

With monitoring function downstream switching devices

Material of optical surface

Plastic

Voltage type

AC/DC

Min. reflector distance

1000mm

With communication interface Ethernet

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.