Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
With time function
No
Max. switching distance
30000mm
Analogue output -10 V ... +10 V
No
Rated switching distance
20000mm
Pre failure notice
No
Max. opening angle
0°
Analogue output 0 mA ... 20 mA
No
With reflector
No
With other analogue output
No
Max. output current
35mA
Scope of delivery of the one-way system
Transmitter and receiver
With communication interface INTERBUS
No
With communication interface SSI
No
With communication interface RS-422
No
Number of protected semiconductor outputs
0
Laser protection class
None
Type of light
Laser diode, infrared light
With communication interface PROFIBUS
No
With communication interface DeviceNet
No
Number of semiconductor outputs with signalling function
0
Number of contact energized outputs with signalling function
0
With communication interface SSD
No
With communication interface analogue
No
With communication interface Ethernet
No
Number of protected contact energized outputs
0
With communication interface AS-Interface
No
With communication interface RS-232
No
With communication interface RS-485
No
Material of cable sheath
Other
With restart blockage
No
Degree of protection (IP)
IP67K
Suitable for safety functions
No
Analogue output 0 V ... 10 V
No
Analogue output 4 mA ... 20 mA
No
Type of interface for safety communication
Other
Explosion safety category for gas
None
Length of sensor
78mm
Material housing
Metal
Switching frequency
250Hz
Setting procedure
Other
With communication interface CANOpen
No
Type of switch function
Programmable/configurable
Type of electric connection
Cable radial
Construction type housing
Cylinder, screw-thread
Type of switching output
PNP/PNP
Ambient temperature
-25 - 55°C
Max. output current at protected output
35mA
Type of safety according to IEC 61496-1
1
Diameter sensor
18mm
Response time
0ms
Explosion safety category for dust
None
Sensing mode
Light switching
Voltage type
AC/DC
Operation agent-safety class
Safety class 0
Material of optical surface
Other
With monitoring function downstream switching devices
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUB0SPSNL2
Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
With time function
Max. switching distance
30000mm
Analogue output -10 V ... +10 V
Rated switching distance
20000mm
Pre failure notice
Max. opening angle
0°
Analogue output 0 mA ... 20 mA
With reflector
With other analogue output
Max. output current
35mA
Scope of delivery of the one-way system
Transmitter and receiver
With communication interface INTERBUS
With communication interface SSI
With communication interface RS-422
Number of protected semiconductor outputs
0
Laser protection class
None
Type of light
Laser diode, infrared light
With communication interface PROFIBUS
With communication interface DeviceNet
Number of semiconductor outputs with signalling function
0
Number of contact energized outputs with signalling function
0
With communication interface SSD
With communication interface analogue
With communication interface Ethernet
Number of protected contact energized outputs
0
With communication interface AS-Interface
With communication interface RS-232
With communication interface RS-485
Material of cable sheath
Other
With restart blockage
Degree of protection (IP)
IP67K
Suitable for safety functions
Analogue output 0 V ... 10 V
Analogue output 4 mA ... 20 mA
Type of interface for safety communication
Other
Explosion safety category for gas
None
Length of sensor
78mm
Material housing
Metal
Switching frequency
250Hz
Setting procedure
Other
With communication interface CANOpen
Type of switch function
Programmable/configurable
Type of electric connection
Cable radial
Construction type housing
Cylinder, screw-thread
Type of switching output
PNP/PNP
Ambient temperature
-25 .. 55°C
Max. output current at protected output
35mA
Type of safety according to IEC 61496-1
1
Diameter sensor
18mm
Response time
0ms
Explosion safety category for dust
None
Sensing mode
Light switching
Voltage type
AC/DC
Operation agent-safety class
Safety class 0
Material of optical surface
Other
With monitoring function downstream switching devices
From same serie