Technical specifications
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Operating distance
0 - 300mm
Operating distance
0 - 300mm
With time function
No
With reflector
No
Max. output current
1.5mA
Analogue output 0 V ... 10 V
No
Analogue output 0 mA ... 20 mA
No
Analogue output 4 mA ... 20 mA
No
Triangulation
Background fade-out
Rated switching distance
120mm
Adjustment range
0 - 300mm
Setting procedure
Other
Voltage type
AC/DC
Rated control supply voltage Us at AC 60HZ
24 - 240V
Laser protection class
Other
With monitoring function downstream switching devices
No
With restart blockage
No
Type of light
Laser diode, infrared light
Suitable for safety functions
No
Degree of protection (IP)
IP67K
Material of cable sheath
Other
Rated control supply voltage Us at DC
24 - 240V
Number of protected contact energized outputs
0
With communication interface RS-485
No
Type of interface for safety communication
Other
With communication interface RS-422
No
Diameter sensor
18mm
Number of semiconductor outputs with signalling function
0
Switching frequency
25Hz
Construction type housing
Cylinder, screw-thread
Max. switching distance
300mm
Pre failure notice
No
With communication interface DeviceNet
No
Number of protected semiconductor outputs
0
Type of switch function
Breaker contact (NC)
Type of switching output
Other
Explosion safety category for dust
Other
With communication interface Ethernet
No
With communication interface RS-232
No
Analogue output -10 V ... +10 V
No
With communication interface PROFIBUS
No
With communication interface SSD
No
Response time
20ms
With communication interface AS-Interface
No
Length of sensor
95mm
With communication interface SSI
No
With communication interface analogue
No
Number of contact energized outputs with signalling function
0
Type of safety according to IEC 61496-1
1
With communication interface INTERBUS
No
Type of electric connection
Connector 1/2 inch
With communication interface CANOpen
No
Explosion safety category for gas
Other
Max. output current at protected output
1.5mA
Ambient temperature
-40 - 70°C
Sensing mode
Light switching
Operation agent-safety class
Safety class 0
Rated control supply voltage Us at AC 50HZ
24 - 240V
Material of optical surface
Plastic
With other analogue output
No
Material housing
Metal
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XU8M18MB230K
Details
- Sensors
- Light scanner with background masking
- 1 KOM
- SCHNEIDER
Technical specifications
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Operating distance
0 .. 300mm
Operating distance
0 .. 300mm
With time function
With reflector
Max. output current
1.5mA
Analogue output 0 V ... 10 V
Analogue output 0 mA ... 20 mA
Analogue output 4 mA ... 20 mA
Triangulation
Background fade-out
Rated switching distance
120mm
Adjustment range
0 .. 300mm
Setting procedure
Other
Voltage type
AC/DC
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Laser protection class
Other
With monitoring function downstream switching devices
With restart blockage
Type of light
Laser diode, infrared light
Suitable for safety functions
Degree of protection (IP)
IP67K
Material of cable sheath
Other
Rated control supply voltage Us at DC
24 .. 240V
Number of protected contact energized outputs
0
With communication interface RS-485
Type of interface for safety communication
Other
With communication interface RS-422
Diameter sensor
18mm
Number of semiconductor outputs with signalling function
0
Switching frequency
25Hz
Construction type housing
Cylinder, screw-thread
Max. switching distance
300mm
Pre failure notice
With communication interface DeviceNet
Number of protected semiconductor outputs
0
Type of switch function
Breaker contact (NC)
Type of switching output
Other
Explosion safety category for dust
Other
With communication interface Ethernet
With communication interface RS-232
Analogue output -10 V ... +10 V
With communication interface PROFIBUS
With communication interface SSD
Response time
20ms
With communication interface AS-Interface
Length of sensor
95mm
With communication interface SSI
With communication interface analogue
Number of contact energized outputs with signalling function
0
Type of safety according to IEC 61496-1
1
With communication interface INTERBUS
Type of electric connection
Connector 1/2 inch
With communication interface CANOpen
Explosion safety category for gas
Other
Max. output current at protected output
1.5mA
Ambient temperature
-40 .. 70°C
Sensing mode
Light switching
Operation agent-safety class
Safety class 0
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Material of optical surface
Plastic
With other analogue output
Material housing
Metal