Aleta.hr

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Rated control supply voltage Us at AC 50HZ

- - -V

Length of sensor

-mm

Width sensor

-mm

Height of sensor

-mm

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Min. reflector distance

-mm

Light dot

-mm²

AWG-number

-

Scope of delivery of the one-way system

Transmitter and receiver

With time function

No

Analogue output 0 mA ... 20 mA

No

Max. opening angle

0°

Setting procedure

Other

Max. output current

35mA

With communication interface analogue

No

With other analogue output

No

Analogue output 4 mA ... 20 mA

No

Max. switching distance

8000mm

Analogue output 0 V ... 10 V

No

Pre failure notice

No

With reflector

No

Analogue output -10 V ... +10 V

No

Rated switching distance

8000mm

With communication interface RS-232

No

With communication interface RS-485

No

With communication interface Ethernet

No

With communication interface SSD

No

With communication interface DeviceNet

No

Operation agent-safety class

Safety class 0

With communication interface CANOpen

No

Type of switching output

PNP/PNP

Explosion safety category for dust

None

Type of switch function

Other

Number of protected contact energized outputs

0

Explosion safety category for gas

None

With communication interface INTERBUS

No

Number of semiconductor outputs with signalling function

0

Type of interface for safety communication

Other

With communication interface SSI

No

Number of contact energized outputs with signalling function

0

Sensing mode

Light switching

Response time

0ms

Material of optical surface

Plastic

Laser protection class

None

Material of cable sheath

Other

Type of light

Other

With communication interface PROFIBUS

No

With communication interface AS-Interface

No

With communication interface RS-422

No

Material housing

Metal

Construction type housing

Cylinder, screw-thread

Type of electric connection

Connector M12

Diameter sensor

18mm

Ambient temperature

-25 - 55°C

With restart blockage

No

Suitable for safety functions

No

Degree of protection (IP)

IP67K

Max. output current at protected output

35mA

Voltage type

AC/DC

Type of safety according to IEC 61496-1

1

Transmission range of the safety field

8m

Switching frequency

500Hz

Number of protected semiconductor outputs

0

With monitoring function downstream switching devices

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XU2S18PP340D

Main Product Image

Details

  • Sensors
  • Through beam photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated control supply voltage Us at AC 50HZ

- .. -V

Length of sensor

-mm

Width sensor

-mm

Height of sensor

-mm

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Min. reflector distance

-mm

Light dot

-mm²

AWG-number

-

Scope of delivery of the one-way system

Transmitter and receiver

With time function

Analogue output 0 mA ... 20 mA

Max. opening angle

0°

Setting procedure

Other

Max. output current

35mA

With communication interface analogue

With other analogue output

Analogue output 4 mA ... 20 mA

Max. switching distance

8000mm

Analogue output 0 V ... 10 V

Pre failure notice

With reflector

Analogue output -10 V ... +10 V

Rated switching distance

8000mm

With communication interface RS-232

With communication interface RS-485

With communication interface Ethernet

With communication interface SSD

With communication interface DeviceNet

Operation agent-safety class

Safety class 0

With communication interface CANOpen

Type of switching output

PNP/PNP

Explosion safety category for dust

None

Type of switch function

Other

Number of protected contact energized outputs

0

Explosion safety category for gas

None

With communication interface INTERBUS

Number of semiconductor outputs with signalling function

0

Type of interface for safety communication

Other

With communication interface SSI

Number of contact energized outputs with signalling function

0

Sensing mode

Light switching

Response time

0ms

Material of optical surface

Plastic

Laser protection class

None

Material of cable sheath

Other

Type of light

Other

With communication interface PROFIBUS

With communication interface AS-Interface

With communication interface RS-422

Material housing

Metal

Construction type housing

Cylinder, screw-thread

Type of electric connection

Connector M12

Diameter sensor

18mm

Ambient temperature

-25 .. 55°C

With restart blockage

Suitable for safety functions

Degree of protection (IP)

IP67K

Max. output current at protected output

35mA

Voltage type

AC/DC

Type of safety according to IEC 61496-1

1

Transmission range of the safety field

8m

Switching frequency

500Hz

Number of protected semiconductor outputs

0

With monitoring function downstream switching devices

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.