Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Width sensor
-mm
Height of sensor
-mm
Max. output current at protected output
-mA
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Max. opening angle
0°
Scope of delivery of the one-way system
Transmitter and receiver
With time function
No
Rated switching distance
15000mm
Max. switching distance
20000mm
Analogue output -10 V ... +10 V
No
With other analogue output
No
Analogue output 0 mA ... 20 mA
No
Analogue output 0 V ... 10 V
No
Laser protection class
Other
Voltage type
AC/DC
With communication interface RS-422
No
With communication interface RS-485
No
Number of protected semiconductor outputs
0
Number of semiconductor outputs with signalling function
1
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
With communication interface SSI
No
Max. output current
200mA
Operation agent-safety class
Safety class 0
Type of interface for safety communication
Other
With communication interface SSD
No
Construction type housing
Cylinder, screw-thread
Explosion safety category for dust
None
With communication interface AS-Interface
No
With communication interface RS-232
No
Switching frequency
25Hz
With reflector
No
Analogue output 4 mA ... 20 mA
No
With monitoring function downstream switching devices
No
With communication interface analogue
No
Material of optical surface
Plastic
Pre failure notice
No
With communication interface PROFIBUS
No
Setting procedure
Manual adjustment
With communication interface Ethernet
No
Type of switching output
2-wire
With communication interface DeviceNet
No
Type of electric connection
Cable radial
With communication interface INTERBUS
No
Sensing mode
Dark switching
Length of sensor
82mm
With communication interface CANOpen
No
Type of light
Infrared light
With restart blockage
No
Material of cable sheath
Other
Suitable for safety functions
No
Degree of protection (IP)
IP67K
Ambient temperature
-25 - 55°C
Rated control supply voltage Us at AC 50HZ
24 - 240V
Type of safety according to IEC 61496-1
1
Rated control supply voltage Us at DC
24 - 240V
Rated control supply voltage Us at AC 60HZ
24 - 240V
Material housing
Metal
Response time
20ms
Explosion safety category for gas
None
Diameter sensor
18mm
Type of switch function
Breaker contact (NC)
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XU2M18MB230
Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Width sensor
-mm
Height of sensor
-mm
Max. output current at protected output
-mA
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Max. opening angle
0°
Scope of delivery of the one-way system
Transmitter and receiver
With time function
Rated switching distance
15000mm
Max. switching distance
20000mm
Analogue output -10 V ... +10 V
With other analogue output
Analogue output 0 mA ... 20 mA
Analogue output 0 V ... 10 V
Laser protection class
Other
Voltage type
AC/DC
With communication interface RS-422
With communication interface RS-485
Number of protected semiconductor outputs
0
Number of semiconductor outputs with signalling function
1
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
With communication interface SSI
Max. output current
200mA
Operation agent-safety class
Safety class 0
Type of interface for safety communication
Other
With communication interface SSD
Construction type housing
Cylinder, screw-thread
Explosion safety category for dust
None
With communication interface AS-Interface
With communication interface RS-232
Switching frequency
25Hz
With reflector
Analogue output 4 mA ... 20 mA
With monitoring function downstream switching devices
With communication interface analogue
Material of optical surface
Plastic
Pre failure notice
With communication interface PROFIBUS
Setting procedure
Manual adjustment
With communication interface Ethernet
Type of switching output
2-wire
With communication interface DeviceNet
Type of electric connection
Cable radial
With communication interface INTERBUS
Sensing mode
Dark switching
Length of sensor
82mm
With communication interface CANOpen
Type of light
Infrared light
With restart blockage
Material of cable sheath
Other
Suitable for safety functions
Degree of protection (IP)
IP67K
Ambient temperature
-25 .. 55°C
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Type of safety according to IEC 61496-1
1
Rated control supply voltage Us at DC
24 .. 240V
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Material housing
Metal
Response time
20ms
Explosion safety category for gas
None
Diameter sensor
18mm
Type of switch function
Breaker contact (NC)
From same serie