Technical specifications

Degree of protection (IP)

IP67K

Voltage type

AC/DC

Material housing

Metal

Rated control supply voltage Us at DC

- - -V

Rated control supply voltage Us at AC 60HZ

24 - 240V

Rated control supply voltage Us at AC 50HZ

24 - 240V

Type of electric connection

Cable radial

Explosion safety category for dust

None

Length of sensor

82mm

Explosion safety category for gas

None

Width sensor

-mm

Construction type housing

Cylinder, screw-thread

Diameter sensor

18mm

With monitoring function downstream switching devices

No

Switching frequency

25Hz

Number of protected semiconductor outputs

0

Type of switching output

Other

Number of semiconductor outputs with signalling function

1

Type of switch function

Normally open contact (NO)

Number of contact energized outputs with signalling function

0

Number of protected contact energized outputs

0

Suitable for safety functions

No

Height of sensor

-mm

Type of interface for safety communication

Other

Max. output current at protected output

1.5mA

Ambient temperature

-25 - 55°C

Max. output current

1.5mA

With restart blockage

No

With communication interface RS-232

No

Response time

2ms

Type of safety according to IEC 61496-1

1

With communication interface Ethernet

No

Material of cable sheath

Other

With communication interface RS-485

No

Transmission range of the safety field

-m

Operation agent-safety class

Safety class 0

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Setting procedure

Other

Analogue output 0 V ... 10 V

No

Analogue output -10 V ... +10 V

No

Analogue output 0 mA ... 20 mA

No

With time function

No

Analogue output 4 mA ... 20 mA

No

Type of light

Infrared light

Laser protection class

Other

Pre failure notice

No

Material of optical surface

Plastic

With other analogue output

No

With communication interface CANOpen

No

With communication interface analogue

No

With communication interface INTERBUS

No

With communication interface AS-Interface

No

With communication interface RS-422

No

With communication interface PROFIBUS

No

With communication interface DeviceNet

No

With communication interface SSD

No

Max. switching distance

20000mm

With communication interface SSI

No

With reflector

No

Sensing mode

Light-/dark switching

Min. reflector distance

-mm

Light dot

-mm²

Rated switching distance

15000mm

AWG-number

-

Scope of delivery of the one-way system

Receiver

Max. opening angle

0°


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XU2M18MA230R

Main Product Image

Details

  • Sensors
  • One-way light barrier
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP67K

Voltage type

AC/DC

Material housing

Metal

Rated control supply voltage Us at DC

- .. -V

Rated control supply voltage Us at AC 60HZ

24 .. 240V

Rated control supply voltage Us at AC 50HZ

24 .. 240V

Type of electric connection

Cable radial

Explosion safety category for dust

None

Length of sensor

82mm

Explosion safety category for gas

None

Width sensor

-mm

Construction type housing

Cylinder, screw-thread

Diameter sensor

18mm

With monitoring function downstream switching devices

Switching frequency

25Hz

Number of protected semiconductor outputs

0

Type of switching output

Other

Number of semiconductor outputs with signalling function

1

Type of switch function

Normally open contact (NO)

Number of contact energized outputs with signalling function

0

Number of protected contact energized outputs

0

Suitable for safety functions

Height of sensor

-mm

Type of interface for safety communication

Other

Max. output current at protected output

1.5mA

Ambient temperature

-25 .. 55°C

Max. output current

1.5mA

With restart blockage

With communication interface RS-232

Response time

2ms

Type of safety according to IEC 61496-1

1

With communication interface Ethernet

Material of cable sheath

Other

With communication interface RS-485

Transmission range of the safety field

-m

Operation agent-safety class

Safety class 0

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Setting procedure

Other

Analogue output 0 V ... 10 V

Analogue output -10 V ... +10 V

Analogue output 0 mA ... 20 mA

With time function

Analogue output 4 mA ... 20 mA

Type of light

Infrared light

Laser protection class

Other

Pre failure notice

Material of optical surface

Plastic

With other analogue output

With communication interface CANOpen

With communication interface analogue

With communication interface INTERBUS

With communication interface AS-Interface

With communication interface RS-422

With communication interface PROFIBUS

With communication interface DeviceNet

With communication interface SSD

Max. switching distance

20000mm

With communication interface SSI

With reflector

Sensing mode

Light-/dark switching

Min. reflector distance

-mm

Light dot

-mm²

Rated switching distance

15000mm

AWG-number

-

Scope of delivery of the one-way system

Receiver

Max. opening angle

0°

From same serie