Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Scope of delivery of the one-way system
Transmitter and receiver
With time function
No
Analogue output 0 V ... 10 V
No
Max. opening angle
0°
Analogue output 4 mA ... 20 mA
Yes
Analogue output 0 mA ... 20 mA
No
Max. switching distance
70000mm
Rated switching distance
50000mm
With other analogue output
Yes
Pre failure notice
No
With reflector
No
Setting procedure
Manual adjustment
Max. output current
100mA
Analogue output -10 V ... +10 V
No
With communication interface analogue
No
With communication interface Ethernet
No
With communication interface RS-485
No
Number of protected semiconductor outputs
1
Number of contact energized outputs with signalling function
1
With communication interface SSI
No
Number of semiconductor outputs with signalling function
1
Type of switch function
Normally open contact (NO)
With communication interface SSD
No
Operation agent-safety class
Safety class 0
Explosion safety category for gas
None
Construction type housing
Cylinder, screw-thread
Max. output current at protected output
100mA
Sensing mode
Dark switching
Diameter sensor
18mm
Response time
15ms
Length of sensor
95mm
Material of optical surface
Plastic
With communication interface INTERBUS
No
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Type of switching output
PNP/PNP
Type of electric connection
Connector M12
Explosion safety category for dust
None
With communication interface PROFIBUS
No
With communication interface DeviceNet
No
With communication interface AS-Interface
No
With communication interface CANOpen
No
With communication interface RS-422
No
With communication interface RS-232
No
Laser protection class
None
With monitoring function downstream switching devices
No
Type of light
Infrared light
Suitable for safety functions
No
Degree of protection (IP)
IP67K
With restart blockage
No
Material of cable sheath
Other
Ambient temperature
-25 - 55°C
Switching frequency
30Hz
Material housing
Metal
Type of safety according to IEC 61496-1
1
Rated control supply voltage Us at DC
12 - 24V
Voltage type
AC/DC
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XU2M18AP20D
Details
- Sensors
- Through beam photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Width sensor
-mm
Height of sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Min. reflector distance
-mm
Light dot
-mm²
AWG-number
-
Scope of delivery of the one-way system
Transmitter and receiver
With time function
Analogue output 0 V ... 10 V
Max. opening angle
0°
Analogue output 4 mA ... 20 mA
Analogue output 0 mA ... 20 mA
Max. switching distance
70000mm
Rated switching distance
50000mm
With other analogue output
Pre failure notice
With reflector
Setting procedure
Manual adjustment
Max. output current
100mA
Analogue output -10 V ... +10 V
With communication interface analogue
With communication interface Ethernet
With communication interface RS-485
Number of protected semiconductor outputs
1
Number of contact energized outputs with signalling function
1
With communication interface SSI
Number of semiconductor outputs with signalling function
1
Type of switch function
Normally open contact (NO)
With communication interface SSD
Operation agent-safety class
Safety class 0
Explosion safety category for gas
None
Construction type housing
Cylinder, screw-thread
Max. output current at protected output
100mA
Sensing mode
Dark switching
Diameter sensor
18mm
Response time
15ms
Length of sensor
95mm
Material of optical surface
Plastic
With communication interface INTERBUS
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Type of switching output
PNP/PNP
Type of electric connection
Connector M12
Explosion safety category for dust
None
With communication interface PROFIBUS
With communication interface DeviceNet
With communication interface AS-Interface
With communication interface CANOpen
With communication interface RS-422
With communication interface RS-232
Laser protection class
None
With monitoring function downstream switching devices
Type of light
Infrared light
Suitable for safety functions
Degree of protection (IP)
IP67K
With restart blockage
Material of cable sheath
Other
Ambient temperature
-25 .. 55°C
Switching frequency
30Hz
Material housing
Metal
Type of safety according to IEC 61496-1
1
Rated control supply voltage Us at DC
12 .. 24V
Voltage type
AC/DC
From same serie
We use cookies to enhance your experience.